Chapter 3
Configuring Fibre Channel Interfaces
S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m
Command
Step 5
switch(config-if)# out-of-service
Putting an interface into out-of-service will
cause its shared resource configuration to
revert to default
Do you wish to continue(y/n)? [n] y
Step 6
switch(config-if)# no out-of-service

Disabling ACL Adjacency Sharing for System Image Downgrade

Fibre Channel ACL adjacency sharing is enabled by default on the switches with an active Generation 2
switching module as of Cisco MDS SAN-OS Release 3.0(3), and with an active Generation 3 module as
of MDS NX-OS Release 4.1(1). Fibre Channel ACL adjacency sharing improves the performance for
zoning and inter-VSAN routing (IVR) network address translation (NAT). To prevent disruptions when
downgrading the system image on your switch to a release prior to Cisco SAN-OS Release 3.0(3), enter
the following command in EXEC mode:
switch# system no acl-adjacency-sharing
To reenable Fibre Channel ACL adjacency sharing on your switch, enter the following command in
EXEC mode:
switch# system acl-adjacency-sharing

Displaying SFP Diagnostic Information

You can use the show interface transceiver command to display small form-factor pluggable (SFP)
diagnostic information for Generation 2 switching modules.
switch# show interface transceiver
...
fc12/12 sfp is present
OL-19445-02, Cisco MDS NX-OS Release 4.2(x)
name is CISCO-FINISAR
part number is FTRJ-8519-7D2CS1
revision is A
serial number is H11TVQB
fc-transmitter type is short wave laser w/o OFC (SN)
fc-transmitter supports intermediate distance link length
media type is multi-mode, 62.5m (M6)
Supported speed is 200 MBytes/sec
Nominal bit rate is 2100 MBits/sec
Link length supported for 50/125mm fiber is 300 m(s)
Link length supported for 62.5/125mm fiber is 150 m(s)
cisco extended id is unknown (0x0)
no tx fault, rx loss, no sync exists, Diag mon type 104
SFP Diagnostics Information
Temperature
:
Voltage
:
Current
:
Optical Tx Power :
Optical Rx Power :
Note: ++
high-alarm; +
Disabling ACL Adjacency Sharing for System Image Downgrade
Purpose
Takes the interface out of service.
Makes the interface available for service.
Repeat
interfaces in the port group.
24.33 Celsius
3.33 Volt
0.04 mA
--
N/A
dBm
--
N/A
dBm
-
high-warning; --
low-alarm; -
Cisco MDS 9000 Family NX-OS Interfaces Configuration Guide
Step 2
through
Step 6
for all the
low-warning