Environmental Conditions

Temperature/
Operating
Humidity
Storage
(Factory packing)
Acoustic noise (operating)
Dust and drip proofness function
 The value measurements are equivalent to JISC0920 (IEC60529:2001) standard. Therefore, safety standard appli-
cation, and failure and breakage of the printer are not guaranteed.
5 to 45°C {41 to 113°F}, 10 to 90% RH (See the operating temperature and
humidity range below.)
-10 to 50°C {14 to 122°F}, 10 to 90% RH (except for paper)
[%RH]
90
65
Operating environment
range
10
5
Approximately 55 dB (bystander position)
Note:
The values above are measured in the Epson evaluation condition.
Acoustic noise differs depending on the paper used, printing contents,
and the setting values, such as print speed or print density.
*
IPX2 equivalent
Note:
Roll paper side is excluded.
When the rubber feet sections are installed horizontally.
34°C, 90%
31°C, 90%
34°C, 75%
40°C, 65%
45°C, 50%
45°C, 43%
34 40 45
[°C]
Ambient temperature
Appendix
Specified original paper other
than below
Specified original paper:
P30521, P30523, P31523, P35524