Certification; Marking, Certificates And Approvals According To The Directive 94/9/Ec (Atex) - MSA ALTAIR 5X Operating Manual

Multigas detectors
Hide thumbs Also See for ALTAIR 5X:
Table of Contents

Advertisement

Available languages

Available languages

6

Certification

See device label for the certification that applies to your specific device.
USA and Canada
USA
USA / NRTL
(Intrinsic Safety,
Non-Mining)
Canada
Canada / CSA
(Intrinsic Safety,
Combustible
Performance, Non-
Mining)
Australia
(Intrinsic Safety,
Industrial and
Mining - TestSafe)
6.1

Marking, Certificates and Approvals According to the Directive 94/9/EC (ATEX)

ALTAIR 5X
Manufacturer:
Product:
EC-Type Examination Certificate:
Type of protection:
Performance
Gas
Marking:
Alkaline
Li-Ion
UL913 for Class I, Div. 1, Groups A, B, C and D, Class II, Div. 1,
-40 °C to +50 °C, T4
CSA C22.2 No. 157 for Class I, Div. 1, Groups A, B, C and D
CSA C22.2 No. 152 M1984 Combustible Performance
Tamb = -40 °C to +50 °C, T4 for Intrinsic Safety
Tamb = -20 °C to +50 °C, T4 for Combustible Performance
ALTAIR5X / ALTAIR5XiR
Ex ia s Zone 0 I IP65
Ex ia s Zone 0 IIC T4 IP65, Tamb = -40 °C to +50 °C
IEC60079-0, IEC60079-1, IEC60079-11, AS-1826
Mine Safety Appliances Company, LLC
1000 Cranberry Woods Drive
Cranberry Township, PA 16066 USA
ALTAIR 5X
EN 60079-0:2012, EN 60079-1:2014, EN 60079-11:2007
EN 60079-18:2009, EN 60079-26:2007, EN 50303:2000
EN 60079-29-1:2007, EN 50104:2010, EN 50271:2010
measuring range 0-100 % LEL:
Methane, Hydrogen, Propane, Butane, Pentane,
Oxygen: measuring range 0-25 Vol %, indication 0-30 Vol %
ALTAIR 5X/ALTAIR 5X IR
FTZU 08 ATEX 0340 X
I M1 Ex ia I Ma
II 1G Ex ia IIC T4 Ga
when combustible XCell sensor is not installed
II 2G Ex db ia mb IIC T4 Gb
Ta = -40 °C to +50 °C
T4: Duracell LR6,MN 1500
Um 6,7 V
IP 65