6.7.2 Backlight (C5.4.0 Backlight)

The signal converter's local display has a colour backlight which can be used to show the NE 107
status. In menu C5.4.0 its behaviour can be configured as described in the following table:
Backlight settings Description
Off
White
Red - Failure
NE107 Color

6.8 Configuration management (C6.3.0 Config. Management)

6.8.1 Load and save configuration (C6.3.2 & C6.3.1)
The signal converter provides functions to store and restore sets of configurations (Backup 1 and
Backup 2). Using the functions in C6.3.2 the present configuration can be stored for later
restoration via C6.3.1.
For documentation purposes please note the checksum for the present configuration (B1.2.0
Change Log).

6.8.2 Factory reset (C6.3.3 Factory Reset)

The signal converter configuration can be reset to factory configuration.
INFORMATION!
Be careful with this function because this process cannot be reverted.

6.8.3 Change log (B1.2.0 Change Log)

Any configuration change of the signal converter is logged within a change log (B1.2.0) with date
and time and a checksum of the signal converter configuration. The change log covers all device
parameters (incl. factory parameters) and provides 128 entries.
07/2016 - 4002075804 - MA MFC 400 R04 en
Backlight always turned off.
Backlight colour is always white.
Backlight colour is set to red in case of a device failure.
Backlight colour is set according to the NE 107 status of the device.