Adam Equipment MDW – 250L User Manual

Adam Equipment MDW – 250L User Manual

Digital physician scale
Hide thumbs Also See for MDW – 250L:

Advertisement

Adam Equipment
MDW – 250L
DIGITAL PHYSICIAN SCALE
Software EMW-250L-20080601
ADAM EQUIPMENT CO. LTD.
p.n. 4302, Rev. C4, November 2009
© Adam Equipment Company 2009

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MDW – 250L and is the answer not in the manual?

Questions and answers

Summary of Contents for Adam Equipment MDW – 250L

  • Page 1 Adam Equipment MDW – 250L DIGITAL PHYSICIAN SCALE Software EMW-250L-20080601 ADAM EQUIPMENT CO. LTD. p.n. 4302, Rev. C4, November 2009 © Adam Equipment Company 2009...
  • Page 2 © Adam Equipment Company 2009 Page 1 Rev C3, June 2008...
  • Page 3: Table Of Contents

    INTRODUCTION ..................4 TECHNICAL SPECIFICATIONS..............4 DISPLAY AND KEY DESCRIPTIONS ............5 SETTING UP THE SCALE................6 FUNCTION ....................5 WEIGHING....................5 MEASURING HEIGHT................6 CALIBRATION ....................6 USER PARAMETERS ..................8 RS232 COMMUNICATIONS.................9 ERROR MESSAGES ..................13 10.0 WARNING....................13 © Adam Equipment Company 2009 Page 2 Rev C3, June 2008...
  • Page 4 © Adam Equipment Company 2009 Page 3 Rev C3, June 2008...
  • Page 5: Introduction

    Environment for Use Temperature: 5ºC-40ºC; Humidity: <85℅ RH Power 12vAC 500mA adapter Battery Internal, re-chargeable 6V 4Ah, 5 hours approx. Calibration External calibration through the keypad. Communications Bi-directional RS232 © Adam Equipment Company 2009 Page 4 Rev C3, June 2008...
  • Page 6: Display And Key Descriptions

    This indicates when the scale is being used with the AC adapter. ZERO This indicator will be displayed in the left corner when the scale reaches zero. The Net weight is displayed, Tare weight is at zero. © Adam Equipment Company 2009 Page 5 Rev C3, June 2008...
  • Page 7: Setting Up The Scale

    • Secure the height rod into the height rod holder (number 4 and 8 on the diagram). indicator cable to indicator screw height rod pole plug socket screw platform height rod holder © Adam Equipment Company 2009 Page 6 Rev C3, June 2008...
  • Page 8: Function

    [Print/Hold] key when the [Print/Hold] key has been set up in the parameter section to work as print function. (Print function is only applied for scale with RS232 interface) © Adam Equipment Company 2009 Page 7 Rev C3, June 2008...
  • Page 9: Measuring Height

    [ON / OFF] key to exit this mode. 5. A few seconds after the [TARE] key has been pressed in step 4 the scale will © Adam Equipment Company 2009 Page 8 Rev C3, June 2008...
  • Page 10 4 for re-calibration. ) 6. Check the calibration by putting the weight that you calibrated at back on the scale, if it is off repeat the calibration process again. © Adam Equipment Company 2009 Page 9 Rev C3, June 2008...
  • Page 11: User Parameters

    1 = Continuously outputs display data. 2 = Output display data when PRINT pressed S.F. 3 = Bi-directional communication (the scale receives and executes commands from the HOST device) © Adam Equipment Company 2009 Page 10 Rev C3, June 2008...
  • Page 12: Rs232 Communications

    No RS232 function. It will not transmit or receive any data although the scale is equipped with RS232. The RS232 function can be only activated when scale is in normal weighing mode. © Adam Equipment Company 2009 Page 11 Rev C3, June 2008...
  • Page 13 <LF> Line Feed character (hex 0AH) <CR> Carriage Return character (hex 0DH) <ETX> End of Text character (hex 03) <SP> Space (hex 20H) H1H2H3 Three status bytes. Refer to Table1 for definition. © Adam Equipment Company 2009 Page 12 Rev C3, June 2008...
  • Page 14 (6) Command: X<CR> (58h 0dh) Response: power off the scale, just like press down the ON/OFF key to turn off the scale. (7) Command: all others Response: Unrecognized command <LF>?<CR><ETX> © Adam Equipment Company 2009 Page 13 Rev C3, June 2008...
  • Page 15 0= eeprom OK always 0 always 0 1= eeprom error always 1 always 1 always 1 always 1 always 1 always 1 always 0 always 1 always 0 parity Parity parity © Adam Equipment Company 2009 Page 14 Rev C3, June 2008...
  • Page 16: Error Messages

    • When lifting the height meter, it is suggested to pull it straight along the pipe without using excessive force. © Adam Equipment Company 2009 Page 15 Rev C3, June 2008...
  • Page 17 © Adam Equipment Company 2009 Page 16 Rev C3, June 2008...
  • Page 18 © Adam Equipment Company 2009 Page 17 Rev C3, June 2008...
  • Page 19 Shielded interconnect cables must be employed with this equipment to insure compliance with the pertinent RF emission limits governing this device. Changes or modifications not expressly approved by Adam Equipment could void the user's authority to operate the equipment. WEEE COMPLIANCE...
  • Page 20 For a complete listing of all Adam products visit our website at www.adamequipment.com © Copyright by Adam Equipment Co. Ltd. All rights reserved. No part of this publication may be reprinted or translated in any form or by any means without the prior permission of Adam Equipment.