ESAB EMP 215ic Instruction Manual page 15

Arc welding equipment
Hide thumbs Also See for EMP 215ic:
Table of Contents

Advertisement

3 TECHNICAL DATA
Wire feed speed
Wire diameter
Mild steel solid wire
Stainless steel solid wire
Flux cored wire
Aluminium
Bobbin size
Dimensions l×w×h
Weight
Operating temperature
Enclosure class
Application classification
Voltage
Primary current
I
GMAW - MIG
max.
I
SMAW - Stick
max.
I
GMAW - MIG
eff.
I
SMAW - Stick
eff.
Permissible load at GMAW - MIG
100% duty cycle
60% duty cycle
40% duty cycle
25% duty cycle
20% duty cycle
Setting range (DC)
Permissible load at SMAW - Stick
100% duty cycle
60% duty cycle
40% duty cycle
0463 407 001
80-475 in./min (2-12.1 m/min) 80-475 in./min (2-12.1 m/min)
.023" (0.6 mm) - .035"
(0.9 mm)
.030" (0.8 mm) - .035"
(0.9 mm)
.030" (0.8 mm) - .045"
(1.1 mm)
.030" (0.8 mm) - 3/64"
(1.2 mm)
Ø 4"- 8" (100-200 mm)
23.0" (548 mm) × 9.0"
(229 mm) × 16.0" (406 mm)
40 lbs (18.2 kg)
-14 to +104 °F (-10 to +40 °C) -14 to +104 °F (-10 to +40 °C)
IP23S
230 V, 1 ~ 50/60 Hz
30 A (27.6 A @25% duty
cycle)
25 A
14 A
13 A
110 A / 19.5 V
125 A / 20.25 V
150 A / 21.5 V
205 A / 24.25 V
-
15 A / 14.75 V -
235 A / 26.0 V
100 A / 24 V
125 A / 25 V
-
- 15 -
EMP 215ic
.023" (0.6 mm) - .035"
(0.9 mm)
.030" (0.8 mm) - .035"
(0.9 mm)
.030" (0.8 mm) - .045"
(1.1 mm)
.030" (0.8 mm) - 3/64"
(1.2 mm)
Ø 4"- 8" (100-200 mm)
23.0" (548 mm) × 9.0"
(229 mm) × 16.0" (406 mm)
40 lbs (18.2 kg)
IP23S
EMS 215ic
120 V, 1 ~ 50/60 Hz
Breaker 15 A: 20.3 A
Breaker 20 A: 28.6 A
Breaker 15 A: 20.8 A
Breaker 15 A: 14.6 A
Breaker 20 A: 18.0 A
Breaker 15 A: 14.7 A
Breaker 15 A: 75 A / 17.75 V
Breaker 20 A: 90 A / 18.5 V
Breaker 15 A: 90 A / 18.5 V
Breaker 20 A: 110 A / 19.5 V
Breaker 15 A: 100 A / 19 V
-
Breaker 20 A: 130 A / 20.5 V
15 A / 14.75 V -
130 A / 20.5 V
65 A / 22.6 V
80 A / 23.2 V
85 A / 23.4 V
© ESAB AB 2017

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ems 215icEm 215ic

Table of Contents