Download Print this page

Toshiba e-STUDIO163 Service Handbook page 92

Multifunctional digital systems
Hide thumbs Also See for e-STUDIO163:

Advertisement

(6)
After the adjustment for the code 411 is completed, apply the same adjustment value for the
code 410.
(Adjustment Mode)
(Key in the same value in the step 5 above)
Press [ENTER] or [INTERRUPT] (Stored in memory).
Note:
Note:
Make sure the first line of the grid pattern is printed out since the line is occasionally vanished.
[C] Reproduction ratio of secondary scanning direction (Fine adjustment of main motor rota-
tion speed (Copier/Printer))
<Procedure>
(1)
While pressing [0] and [5] simultaneously, turn the power ON.
(2)
Press [1]
[INTERRUPT]. (A grid pattern with 10 mm squares is printed out. Use A3/LD from
standard drawer of the equipment.
(3)
Check the grid pattern on the test chart printed out and measure the distance C from the 10th
line at the leading edge of the paper to the 30th line of the grid pattern.
* Normally, the 1st line of the grid pattern is not printed.
(4)
Check if the distance C is within 200±0.5 mm.
(5)
If not, use the following procedure to change values and measure the distance C again.
(Adjustment Mode)
(Key in a value (acceptable values: 0 to 255))
[ENTER] or [INTERRUPT] (Stored in memory)
"100% A" is displayed
Press [1]
[INTERRUPT]
* The larger the adjustment value is, the longer the distance C becomes (approx. 0.125 mm/
step).
e-STUDIO163/203 ADJUSTMENT
(Key in the code [410])
(Key in code [421])
(A grid pattern is printed out.)
3 - 8
[START]
(Adjustment mode)
[START]
December 2005 © TOSHIBA TEC

Advertisement

loading

This manual is also suitable for:

E-studio203