Classifi-
Code
cation
1131
User
Maximum number of time
interface
job build performed
1133
Paper
Feeding direction setting of
feeding
envelope
1135
Paper
Default setting of drawers
feeding
(Printer/BOX)
1140
User
Restriction of the template
interface
function with the adminis-
trator privilege
1372
Counter
Heater and energizing time
accumulating counter Dis-
play/0 clearing
1378
Counter
Counter for period of time
fuser unit is at ready tem-
perature
1380
Counter
Counter for period of time
fuser unit is at printing tem-
perature
1382
Counter
Counter for period of time
fuser unit is at energy sav-
ing temperature/Counter
reset
1385
Image
Number of output pages
process-
(Thick paper 1)
ing
1386
Image
Number of output pages
process-
(Thick paper 2)
ing
1388
Image
Number of output pages
process-
(OHP film)
ing
1390
Paper
Feeding retry counter
feeding
(Drawer)
December 2005 © TOSHIBA TEC
Setting mode (08)
Default
Func-
<Accept-
Items
tion
value>
ALL
<5-1000>
ALL
PRT
ALL
ALL
<8 digits>
ALL
<8 digits>
ALL
<8 digits>
ALL
<8 digits>
ALL
<8 digits>
ALL
<8 digits>
ALL
<8 digits>
ALL
<8 digits>
e-STUDIO163/203 ERROR CODE AND SELF-DIAGNOSTIC MODE
2 - 59
RAM
Contents
able
1000
M
Sets the maximum
number of time a job
build has been per-
formed.
5-1000: 5 to 1000 times
0
M
Sets the feeding direc-
<0-1>
tion of envelopes.
0: Envelope flap comes
on its trailing edge
(front side of the
equipment)
1: Envelope flap comes
on its leading edge
(rear side of the
equipment)
1
M
1: LCF
<1-5>
2: Drawer
3: PFU
4: Invalid
5: Invalid
0
M
Selects the restriction of
<0-1>
the template function
usage setting.
0: No restriction
1: Only available with
the administrator
privilege.
0
M
Counts up the heater
control time accumu-
lated (when power of
the equipment is ON)
but does not count at
the Sleep Mode.
0
M
Counts up the heater
control time accumu-
lated (when the equip-
ment is at ready status).
0
M
Counts up the heater
control time accumu-
lated (during printing).
0
M
Counts up the heater
control time accumu-
lated (when the equip-
ment is in the Energy
Saving Mode).
0
M
Counts up when the
registration sensor is
ON.
0
M
Counts up when the
registration sensor is
ON.
0
M
Counts up when the
registration sensor is
ON.
0
M
Counts the number of
times of the feeding
retry from the Drawer.
Proce-
dure
1
2
1
1
1
1
1
1
1
1
1
1
1

Advertisement