Marstair CWW 15 Installation Instruction page 3

May be installed at low or high level

Advertisement

Air Deflection
Air deflection is set by manually adjusting the vanes. The unit is supplied with front discharge but can be changed to top
discharge as follows.
1
Remove the filters.
2
Remove the end covers.
3
Using a screwdriver or thin bladed
tool, release the three tabs at the
bottom of the top box; these are
directly below the centre and two end
vertical vanes.
4
Lift the top box assembly from the
unit.
5
By gently flexing the top box sides
from the rear, transfer the deflector
plate from the upper to the lower two
fixing holes.
6
Rotate the top box assembly and refit
to give top discharge.
CWW WIRING DIAGRAM
KEY
ABBR MEANING
B
BROWN
R
RED
O
ORANGE
YELLOW
Y
G
GREEN
BL
BLUE
GRY GREY
W
WHITE
BK
BLACK
P
PINK
M1
MOTOR FAN
M2
PUMP
PCB1 CONDENSATE CONTROL
RT
REMOTE THERMOSTAT
F
FUSE
S1
CONDENSATE SENSOR
CAPACITOR
C
V1
VALVE COOL
V2
VALVE HEAT
CC
CONTROL
Installation Instruction
96908015-03