Troubleshooting - Kärcher HDS 3.5/23-4M Eg Operating Instructions Manual

Hide thumbs Also See for HDS 3.5/23-4M Eg:
Table of Contents

Advertisement

Available languages

Available languages

 Clean sieve in water and reinstall.
Cleaning the fine filter
 Unpressurize the appliance.
 Unscrew the fine filter from the pump
head.
 Remove the fine filter and the filter in-
sert.
 Clean the filter with clean water or com-
pressed air.
 Reinstall in reverse sequence.
Clean sieve in the water shortage safe
guard
 Loosen covering nut and take off hose.
 Take out sieve.
Note: If necessary turn in screw M8 appr.
0.2 in/5 mm inwards and therewith pull out
sieve.
 Clean sieve in water.
 Push sieve inwards.
 Put on hose.
 Tighten covering nut firmly.
Clean filter at the detergent suck hose
 Take out detergent suck supports.
 Clean filter in water and reinstall.
Oil change
 Ready a catch bin for appr. 0.26 gal/
1 Liter oil.
 Loosen release screw.
Dispose of old oil ecologically or turn in at
a gathering point.
 Tighten release screw.
 Fill oil slowly up to the MAX marking.
Note: Air pockets must be able to leak out.
For oil type refer to technical specifica-
tions.

Troubleshooting

Danger
Risk of injury by inadvertent startup of ap-
pliance and electrical shock.
First pull out the plug from the mains before
carrying out any tasks on the machine.
16
Indicator lamp pump
1x blinking
Lack of oil
 Replenish oil.
2x blinking
Leak in the high pressure system
 Check high pressure system and con-
nections for tightness.
3x blinking
Water shortage
 Check water supply, check connec-
tions.
4x blinking
Obstructed reed switch in the water
shortage safe guard.
 Check water shortage safe guard.
Indicator lamp "Ready for use"
No line voltage, see "Appliance is not
running".
Engine indicator lamp
1x blinking
Contactor error
 Set the appliance switch to "0/OFF".
 Turn on the appliance.
Error occurs repeatedly.
 Inform Customer Service
2x blinking
Engine overload/overheat
 Set the appliance switch to "0/OFF".
 Allow device to cool down.
 Turn on the appliance.
Error occurs repeatedly.
 Inform Customer Service
3x blinking
Fault in the voltage supply.
 Check main connections and mains
fuse.
4x blinking
Excessive power consumption.
– 9
EN
turns off

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hds 4.5/22-4m eaHds 4.0/20-4m eaHds 3.5/30 ea cage

Table of Contents