Control Port Functions; Scaler I/O Port Functions (Pw190) - Eiki LC-XBM26 Service Manual

Hide thumbs Also See for LC-XBM26:
Table of Contents

Advertisement

Control Port Functions

Scaler I/o Port Functions (PW190)

PIN
Port
Port NAMe FuNctIoN
No.
No.
1
A1
PORTD7
11
A11
PORTC5
26
A26
RXD1
101
B2
PORTD6
124
B25
TXD_PW
99
C1
PORTE
202
C12
PORTC2
205
E15
PORTC0
208
C18
PORTH5
211
C21
PORTH1
212
C22
PORTH7
28
C26
ADC1
191
D2
PORTE4
276
D
PORTE1
278
D5
PORTD5
284
D11
PWM1
285
D12
PORTC
290
D17
PORTH4
29
D20
PORTH6
294
D21
PORTH
295
D22
TXD1
215
D24
ADC0
126
D25
ADC2
190
E2
PORTE7
275
E
PORTE5
52
E4
PORTE2
5
E5
PORTE0
62
E14
PORTC4
68
E20
PORTH0
216
E24
ADC
127
E25
ADC7
0
E26
DAC1
96
F1
PORTF4
189
F2
PORTF1
420
F5
PORTF2
298
F2
ADC4
128
F25
DAC2
74
J22
DAC
184
L2
PORTB6
89
N1
PORTA
267
N
PORTA6
44
N4
PORTA7
200
C10
PWM
201
C11
PORTC7
110
B11
PORTC6
111
B12
PORTC1
67
E19
THRWSC
214
C24
IRRCVR0
474
N6
PORTA2
41
N5
PORTA4
182
N2
PORTA5
90
M1
PORTA0
18
M2
PORTA1
9
J1
INIB9
187
H2
INIB2
94
H1
INIB
188
G2
INIG7
95
G1
INIG9
27
G
INIG5
2-Wire Serial Data 2
2-Wire Serial Clock 1
2-Wire Serial Data 0
ADC1
2-Wire Serial Clock 2
2-Wire Serial Clock 0
2-Wire Serial Data 1
ADC0
ADC2
ADC
ADC7
DAC1
ADC4
DAC2
DAC
SIGNAL
deScrIPtIoN
NAMe
MIC_OFF
MIC Control
PW_UPDATE
RXD_MCI
Network RXD
DDC_SW
TXD_PW
Serial Control RXD
READY_LED
SDATA_PW
-Wired Serial Control Data
PW_NMCLR
LAN control
SDA2
IIC Bus Switch IC DAC, SoundIC[5V_SW]
SCL1
SDA0
IIC Bus Temp Sensor [ ]
KEY1
Input/Select/Keystone
PW_MASTER_SCK
TEMP_LED
LED on:H
RESET_MIC
MIC RET
BLAST_AC
Ballast CTL
LAMP_DET
Lamp retry detect, High=Retry
SCL2
IIC Bus Control Clock
SCL0
IIC Bus Control Clock
SDA1
IIC Bus Control Data
TXD_MCI
Network TXD
P_FAIL
Power Failure Signal Input, Failure:L
KEY-2
Key Control Input
FAN_SW1
Fan Control Swicth 1
PW_MASTER_SD0 Sub CPU Communication
LAMP_LED
LED on:H
POWER_LED
LED on:H
PW_NET_HIL
LAN control
RXD_PW
Serial Control RXD
SENSOR_T
Keystone Sensor
SENSOR_X
Keystone Sensor
FAN CON_A
FAN CON_A
ON_16V
Standby Power Control
PW_MASTER_SDI Sub CPU Communication
POWER_SW_LAN Netwokr Power SW
Option SW
Option Switch
FAN CON_B
FAN CON_B
FAN_CON_C
FAN_CON_C
POW_KEY
Power On Key, H:ON
LAMP_DC_ON Power Control, Power On: H
MUTE
High=MUTE_ON
MONIT_OUT
Low=in, High=Monit OUT
LAMP-PWM
Light adjust
SV_IRIS
IRIS control
S.V_IRIS
IRIS control
SCS_PW
 wired serial control data
SCLK_PW
 wored serial clock
RIC_PW
PIC RECEIVER
IRIS_STAT
IRIS STAT control
MODEL_OPTION XBM26=High, XBM21=Low
AMP_STBY
Audio control
IRIS-CW
IRIS control
IRIS_RST
IRIS control
IRIS_STB
IRIS control
IRIS_CK
IRIS control
IRIS_EN
IRIS control
ON_V
Power control
ON_150V
Power control
IRM_IRT
LE0711 reset
-66-
I/o
O
O
I
O
O
O
O
I
O
O
O
I
O
O
I
O
I
O
O
O
O
I
I
O
O
O
O
O
I
I
I
O
I
I
I
I
O
O
I
O
O
O
O
O
O
O
O
I
I
O
O
O
O
O
O
O
O
O
O