Electrical Adjustments
Group/
Item Name
Item
Temp A Warning Offset
15
(Temp)
16 Temp B Warning Offset
(Temp)
Temp C Warning Offset
17
(Temp)
18 Temp B-A Warning Offset
(Temp)
19 Temp C-A Warning Offset
(Temp)
20 Temp A Warning Offset
(Time)
21 Temp B Warning Offset
(Time)
Temp C Warning Offset
22
(Time)
Temp B-A Warning Offset
2
(Time)
24 Temp C-A Warning Offset
(Time)
Lc-XBM26
Group
Fan tem error Setting (Memorized)
253
0 Temp A Warning (High)
1 Temp B Warning (High)
2 Temp C Warning (High)
 Temp B-A Warning(High)
4 Temp C-A Warning(High)
5 Temp A Warning (Normal)
6 Temp B Warning (Normal)
7 Temp C Warning (Normal)
8 Temp B-A Warning (Normal)
9 Temp C-A Warning (Normal)
10 Temp A Warning (Eco)
11 Temp B Warning (Eco)
12 Temp C Warning (Eco)
1 Temp B-A Warning (Eco)
14 Temp C-A Warning (Eco)
Temp A Warning Offset
15
(Temp)
Temp B Warning Offset
16
(Temp)
Temp C Warning Offset
17
(Temp)
Temp B-A Warning Offset
18
(Temp)
Temp C-A Warning Offset
19
(Temp)
Temp A Warning Offset
20
(Time)
Temp B Warning Offset
21
(Time)
Temp C Warning Offset
22
(Time)
Temp B-A Warning Offset
2
(Time)
24 Temp C-A Warning Offset
(Time)
Lc-XBM21
Group
Fan control range Setting (temp./Voltage)
254
0 High Fan Control Min Temp
1 High Fan Control Max Temp
2 High Fan1 Min
 High Fan1 Max
4 High Fan2 Min
5 High Fan2 Max
Function
Offset of Temp Error (Temp.)
Error Setting Value is increased XC at
the below condition
* Standby
* Right to turn on the lamp
*Right to change the Lamp mode
Offset of Temp Error (Minutes)
Error Setting Value is increased X min-
ute at the below condition
* Standby
* Right to turn on the lamp
*Right to change the Lamp mode
Temp. A to judge the Temp Error at
Normal (Room)
Temp. B to judge the Temp Error at
Normal (Panel)
Temp. C to judge the Temp Error at
Normal (Lamp)
Temp. B-A to judge the Temp Error at
Normal (Clogging Det.)
Temp. C-A to judge the Temp Error at
Normal (Clogging Det.)
Temp. A to judge the Temp Error at
Eco (Room)
Temp. B to judge the Temp Error at
Eco(Panel)
Temp. C to judge the Temp Error at
Eco(Panel)
Temp. B-A to judge the Temp Error at
Normal (Clogging Det.)
Temp. C-A to judge the Temp Error at
Normal (Clogging Det.)
Offset of Temp Error (Temp.)
Error Setting Value is increased XC at
the below condition
* Standby
* Right to turn on the lamp
*Right to change the Lamp mode
Offset of Temp Error (Minutes)
Error Setting Value is increased X min-
ute at the below condition
* Standby
* Right to turn on the lamp
*Right to change the Lamp mode
Initial
5
5
5
0
0





HiLand-
HiLand-
Normal Ceiling
Normal
Ceiling
45
51
47/48
49/50
58
6
58
6
6
68
6
68
100
100
100
100
100
100
100
100
45
50
46/47
48/49
58
6
58
6
6
68
6
68
100
100
100
100
100
100
100
100
45
46
46
47/48
58
58
58
58
62
62
62
62
100
100
100
100
100
100
100
100
5
5
5
0
0





Normal Ceiling HiLand-
HiLand-
Normal
Ceiling

5
/4
5/6
40
46
40/42
4/44
68
68
8/9
85/95
15
15
15
15
7
85
88/100
101/11
96
101
112/124 117/129
-48-
range
Note
0-100
0-100
0-100
0-100
0-100
0-5
0-5
0-5
0-5
0-5
-
On1/On2
-
-
-
-
0-100
On1/On2
0-100
0-100
0-100
0-100
0-100
On1/On2
0-100
0-100
0-100
0-100
0-100
0-100
0-100
0-100
0-100
0-5
0-5
0-5
0-5
0-5
-
On1/On2
-
On1/On2
-
On1/On2
-
-
On1/On2
-
On1/On2