Electrical Adjustments
Group
Item Name
/Item
17 Close Limit Dimmer 7
18 Close Limit Dimmer 8
19 Close Limit Dimmer 9
20 Close Limit Dimmer 10
21 Close Limit Dimmer 11
22 Close Limit Dimmer 12
2 Close Limit Dimmer 1
24 Close Limit Dimmer 14
25 Close Limit Dimmer 15
0 Update Interval
Group
VBI Slice Level
230
0 Generic Initial Slicing Level
1 Generic High Level Threshold PW190 register 0xE45
2 Generic Low Level Threshold PW190 register 0xE46
 Generic Minimum Low Level PW190 register 0xE47
4 Generic Maximum High Level PW190 register 0xE48
Group
FAN control
250
0 FAN1 MIN ADJUST (DAC)
1 FAN1 MAX ADJUST (DAC)
2 FAN2 MIN ADJUST (DAC)
 FAN2 MAX ADJUST (DAC)
4 FAN MIN ADJUST (DAC)
5 FAN MAX ADJUST (DAC)
6 Not used
7 Not used
Group
FAN option
252
0 HI-LAND SWITCH
1 SAFETY SWITCH
2 FAN MANUAL SWITCH
 FAN1 MANUAL VOLTAGE
4 FAN2 MANUAL VOLTAGE
5 FAN MANUAL VOLTAGE
6 Not used
Lc-XBM21
Group
Fan tem error Setting (Memorized)
253
0 Temp A Warning (High)
1 Temp B Warning (High)
2 Temp C Warning (High)
 Temp B-A Warning(High)
4 Temp C-A Warning(High)
5 Temp A Warning (Normal)
6 Temp B Warning (Normal)
7 Temp C Warning (Normal)
8 Temp B-A Warning (Normal)
9 Temp C-A Warning (Normal)
10 Temp A Warning (Eco)
11 Temp B Warning (Eco)
12 Temp C Warning (Eco)
1 Temp B-A Warning (Eco)
14 Temp C-A Warning (Eco)
Function
PW190 register 0xE44
DAC Output for Fan
Adjust the tolerance of DAC and Fan
Volage.
* Lamp mode is forced Eco
0: Normal, 1: Hi-Land, 2-4: Hi-Land
1-
For test purpose
0: Auto, 1: Manual
Fan Voltage (unit : 0.1V)
Effective only when Fan Manual
switch is 1
Temp. A to judge the Temp Error at
Normal (Room)
Temp. B to judge the Temp Error at
Normal (Panel)
Temp. C to judge the Temp Error at
Normal (Lamp)
Temp. B-A to judge the Temp Error at
Normal (Clogging Det.)
Temp. C-A to judge the Temp Error at
Normal (Clogging Det.)
Temp. A to judge the Temp Error at
Eco (Room)
Temp. B to judge the Temp Error at
Eco(Panel)
Temp. C to judge the Temp Error at
Eco(Panel)
Temp. B-A to judge the Temp Error at
Normal (Clogging Det.)
Temp. C-A to judge the Temp Error at
Normal (Clogging Det.)
Initial
54
504
474
444
414
84
54
24
294
18/18
9
0
0
0
255
8
2
8
20
1
214
0
0
0
100
100
100
-
Normal Ceiling HiLand-
HiLand-
Normal
Ceiling
45
51
48
50
58
6
58
6
6
68
6
68
100
100
100
100
100
100
100
100
45
50
46/47
48/49
58
6
58
6
6
68
6
68
100
100
100
100
100
100
100
100
50
51
46
47/48
6
6
58
58
67
67
62
62
100
100
100
100
100
100
100
100
-47-
range
Note
0-102
0-102
0-102
0-102
0-102
0-102
0-102
0-102
0-102
0-102
(AV/PC)
0-255
0-255
0-255
0-255
0-255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 5
0 - 6
0 - 
0 - 255
0 - 255
0 - 255
-
-
-
-
-
0-100
On1/On2
0-100
0-100
0-100
0-100
0-100
On1/On2
0-100
0-100
0-100