Electrical Adjustments
Group/
Item Name
Item
10 BLIND SECTOR BIAS
Group
Option
200
0 Logo Prohibition
1 RS232C Baudrate
2 PJLink Enable
4 CABLE SW
5 PW Debug Command
Enable
6 Device Refresh Disable
7 Device Access Disable
Lamp PWM PresAv
40
50Hz
Lamp PWM PresAv
41
60Hz
42 Lamp PWM PresUnlock
43 Lamp PWM PresPcA
44 Lamp PWM PresPcB
45 Lamp PWM PrefHAv50Hz
46 Lamp PWM PrefHAv60Hz
47 Lamp PWM PrefHUnlock
50 Lamp Replacement Display
51 Filter Warning Display
52 Lamp Counter Reset Times
53 Filter Counter Reset Times
Factory Default Execute
54
Times
56 Menu Position
57 Menu Position
59 Source Search Enable
60 Language Default Setting
65 Mute Setting In Freeze status Mute On/Off in Freeze status
66 Iris Warning Display
Group
Option (signal)
201
0 FrameLock Option
2 Field Sense Invert Enable
4 Sub Image Enable
6 Zoom Accelerator Enable
7 DZoom Reset by Keystone
8 Stability Count
Sensivity for Signal Lost
9
(HSYNC)
10 Sensivity for Signal Lost
(VSYNC)
11 Keystone Filter Center Value Reference Value
Group
Spread Spetrum
205
0 Enable
1 Modulation frequency
2 Diffusivity
Function
Logo Prohibition (0: Menu, 1: Forced,
2: For China)
Baud Rate
PJLink
Long Cable
Filter Warning Display On / Off
Reset Times of Lamp Counter
Filter Counter Reset Times
Reset times of Fanctory Default
Move menu (X asis)
Move menu (Y asis)
Source Search Enable
(0: Disable 1:Enable)
Language Default setting
(0: English 1:Japanese)
Iris Warning Display On / Off
Count Value of V-missing
Only used this value for No Signal
Judgement(Hz)
Only used this value for No Signal
Judgement(Line)
0=Enable , 1=Disable
Initial
61
0
0
1
0
0
0
0
80
67
65
2
3
5000
5000
5000
1
1
0
0
0
0
0
1
0
1
1
1
0
1
0
0
5
350
3
16
1
300
200
-45-
Range
Note
0 - 1024
0 - 1
Effective after AC On
0: 19200bps, 1: 9600bps,
0 - 2
2: 115200bps
0 - 1
0: Disable 1: Enable
0 - 1
0: Disable, 1: Enable
0:Disable (Serial Command Eanble)
0 - 1
1: Enable (PW Debug Mode)
0:Enable, 1:Disable
0 - 1
No last memory
0:Enable (Normal), 1:Disable
0 - 1
No last memory
0-255
0-255
0-255
0-255
0-255
0-65535
0-65535
0-65535
0-1
0-1
1: On, 0: Off
0-255
Read only
0-255
Read only
0 - 255
Read only
0 - 1024
0 - 1024
0-1
0-1
0-1
1: On, 0: Off
0-1
1: On, 0: Off
0: FrameLockOFF at PC signal
1: FrameLockON at PC signal and
0 - 1
47Hz (Vfreq) ~ Panel frequency of
input signal
Reverse Processing of
FLDINVSetting Value
0: Disable - Used FLDINV Setting
0 - 1
Value
1: Enable - Used Reversed FLDINV
Setting Value
0:Disable (Service Adjustment
Dsiable, Used all the Center Values
0 - 1
1:Enable (Service Adjustment
Enable)
0:Zoom Accelerator OFF ,
0 - 1
1:Zoom Accelerator ON
No last memory
0:Enable (Normal), 1:Disable (Dzoom
is not cancelled even if Keystone is
0 - 1
cancelled)
No last memory
0 - 255
0 - 32767
0 - 255
0 - 30
0-1
1-500
0-300