Electrical Adjustments
Group/
Item Name
Item
6 High Fan3 Min
7 High Fan3 Max
10 Normal Fan Control Min Temp
Normal Fan Control Max
11
Temp.
12 Normal Fan1 Min
13 Normal Fan1 Max
14 Normal Fan2 Min
15 Normal Fan2 Max
16 Normal Fan3 Min
17 Normal Fan3 Max
20 Eco Fan Control Min Temp
21 Eco Fan Control Max Temp
22 Eco Fan1 Min
23 Eco Fan1 Max
24 Eco Fan2 Min
25 Eco Fan2 Max
26 Eco Fan3 Min
27 Eco Fan3 Max
LC-XBM26
Group
Fan Control Range Setting (Temp./Voltage)
254
0 High Fan Control Min Temp
1 High Fan Control Max Temp
2 High Fan1 Min
3 High Fan1 Max
4 High Fan2 Min
5 High Fan2 Max
6 High Fan3 Min
7 High Fan3 Max
10 Normal Fan Control Min Temp
11 Normal Fan Control Max
Temp.
12 Normal Fan1 Min
13 Normal Fan1 Max
14 Normal Fan2 Min
15 Normal Fan2 Max
16 Normal Fan3 Min
17 Normal Fan3 Max
20 Eco Fan Control Min Temp
21 Eco Fan Control Max Temp
22 Eco Fan1 Min
23 Eco Fan1 Max
24 Eco Fan2 Min
25 Eco Fan2 Max
26 Eco Fan3 Min
27 Eco Fan3 Max
Group
Fan Start/Cooling Setting
255
0 Fan1 Initial Volt
1 Fan2 Initial Volt
2 Fan3 Initial Volt
4 Fan1 Cooling Speed
5 Fan2 Cooling Speed
6 Fan3 Cooling Speed
8 Cooling Time L1
9 Cooling Time L2
10 Temp Error Cooling Time
11 OnStart Cooling Start Thresh-
old
12 After shutdown cooling
Group
Fan/Lamp Voltage Dimmer Setting
256
2 Fan 1 Speed Gain
3 Fan 2 Speed Gain
Function
Temp Sensor Control Start/End Temp.
at Normal
Fan voltage value at Normal (unit:
0.1V)
Temp Sensor Control Start/End Temp.
at Eco
Fan voltage value at Eco (unit: 0.1V)
Fan voltage value at Eco (unit: 0.1V)
Temp Sensor Control Start/End Temp.
at Normal
Fan voltage value at Normal (unit:
0.1V)
Temp Sensor Control Start/End Temp.
at Eco
Fan voltage value at Eco (unit: 0.1V)
Fan Start Voltage(0.1V)
Fan Voltage at Power Off (0.1V)
Cooling Time setting at Fan Mode L1
(x 30 sec) 1: 30, 3: 90, 15: 450 sec.
Cooling Time setting at Fan Mode L2
(x 30 sec)
1: 30, 3: 90, 15: 450 sec.
Cooling Time setting at Temp Erro (x
30 sec)
Cooling after shutdown (0: No, 1: Yes)
Initial
75
80
85/100
90/105
135
135
135
135
33
35
33/34
35
40
45
40/41
42/43
58
58
80/90
85/95
135
135
135
135
71
81
95/107
106/118
108
113
132/144 137/149
70
75
85/100
90/105
135
135
135
135
34
35
32/33
34
45
46
40
41/42
50
50
65/70
70/75
147
147
125
125
45
45
48/60
48/60
73
80
68/ 80
73/85
55
60
60/75
65/80
135
135
115
115
HiLand-
HiLand-
Normal Ceiling
Normal
Ceiling
33
35
33/34
35/36
40
46
40/42
43/44
68
68
83/93
85/95
135
135
135
135
75
85
88/100
98/110
100
105
113/125 118/130
80
85
85/100
90/105
135
135
135
135
33
35
33/34
35
40
45
40/41
42/43
58
58
80/90
85/95
135
135
135
135
73
85
88/100
101/113
96
101
112/124 117/129
75
80
85/100
90/105
135
135
135
135
34
35
32/33
34
40
41
40
41/42
50
50
60/70
65/75
120
120
125
125
45
45
48/60
48/60
65
70
68/80
73/85
55
60
60/75
65/80
110
110
115
115
55
55
55
135
100
135
2
3
3
38
1
10
10
-49-
Range
Note
-
On1/On2
-
20-100
On1/On2
20-100
On1/On2
0-255
On1/On2
0-255
0-255
On1/On2
0-255
On1/On2
0-255
On1/On2
0-255
20-100
On1/On2
20-100
On1/On2
0-255
On1/On2
0-255
0-255
On1/On2
0-255
On1/On2
0-255
On1/On2
0-255
-
On1/On2
-
On1/On2
-
On1/On2
-
-
On1/On2
-
On1/On2
-
On1/On2
-
20-100
On1/On2
20-100
On1/On2
0-255
On1/On2
0-255
0-255
On1/On2
0-255
On1/On2
0-255
On1/On2
0-255
20-100
On1/On2
20-100
On1/On2
0-255
On1/On2
0-255
0-255
On1/On2
0-255
On1/On2
0-255
On1/On2
0-255
0-255
0-255
0-255
0-255
0-255
0-255
1-15
1-15
1-15
0-100
0-1
0-255
0-255