Refrigerant Connections / Recommended Liquid And Vapor Tube Diameters; Accessory Usage - Carrier 25HNA6 Installation Instruction

Infinity series heat pump with puron refrigerant 2 to 5 nominal tons (sizes 24 to 60)
Hide thumbs Also See for 25HNA6:
Table of Contents

Advertisement

Table
1 - Refrigerant
Connections
and Recommended
Liquid
and Vapor Tube Diameters
(in.)
Information
is Specific
to 25HNA6
and 25HNA9
Models
UNIT SIZE
25HNA624
25HNA636
25HNA648
25HNA660
RATED VAPOR*
Tube
Diameter
5/8
3/4
7/8
1- 1/8
Connection
Diameter
3/8
3/8
3/8
3/8
LIQUID
Tube
Diameter
3/8
3/8
3/8
3/8
Connection
Diameter
5/8
3/4
7/8
7/8
3/4
3/4
7/8
1 - 1/8
Tube diameters
are for total equivalent
lengths (T.E.L.) up to 80 ft. (24.38 m) Consult the Long Line Guideline--Air
Conditioners
and Heat Pumps using
Puron¢_ refrigerant.
Do not apply capillary tube or the fixed orifice indoor coils to these units.
For Tubing Set lengths between 80 and 200 ft. (24.38 and 60.96 m) horizontal
or 20 ft. (6.10 m) vertical differential
(250 ff./76.2 m Total Equivalent
Length),
refer to the Longline
Guideline-
Air Conditioners
and Heat Pumps using Puron ® Refrigerant.
25HNA924
3/8
3/8
3/4
25HNA936
3/8
3/8
3/4
25HNA948
3/8
3/8
7/8
25HNA960
3/8
3/8
7/8
Units are rated with 25 ft. (7.6 m) of lineset.
See Product Data sheet for performance
data when using different
size and length linesets.
Notes:
1.
2.
3
Table
2 - Accessory
Usage
REQUIRED
FOR
REQUIRED
FOR
LONG
LINE
REQUIRED
FOR
SEA
LOW-AMBIENT
COOLING
ACCESSORY
APPLICATIONS*
COAST
APPLICATIONS
APPLICATIONS
(Over
80 ft/24.38
m)
(Within
2 miles/3.22
km)
(Below
55°F/12.8
° C)
Crankcase
Heater
Standard
Standard
Standard
Standard
with
Infinity"
Control
Evaporator
Freeze
Protection
(Low Ambient not allowed with non-
No
No
communicating
thermostat)
Standard
with
Infinity
Control
Winter
Start
Control
(Low Ambient not allowed with non-
No
No
communicating
thermostat)
Standard
on 25HNA6
models.
Standard
on 25HNA6
models.
Standard
on 25HNA6
models.
Compressor
Start
Assist
Capacitor
Not required
on 25HNA9
models
Not required
on 25HNA9
models
Not required
on 25HNA9
and Relay:[:
since compressor
always
starts
since compressor
always
starts
models
since compressor
unloaded,
unloaded,
always
starts
unloaded.
Standard
with
Infinity
Control
(Low
Low-Ambient
Control
ambient not allowed with non-commu-
No
No
nicating thermostat)
Support
Feet
Recommended
No
Recommended
Liquid-
Line
Solenoid
Valve
No
Yes
No
Puron
Refrigerant
Balance
Port
Yest
Yest
Yest
Hard-
ShutOff
TXV
For tubing set lengths between 80 and 200 ft. (24.38 and 60.96 m) horizontal
or 20 ft. (6.10 m) vertical differential
(total equivalent
length), refer to the Long
Line Guideline--Air
Conditioners
and Heat Pumps using Purcn® Refl'igerant.
1- Required on all indoor units. Standard on all new Purcn refrigerant
fan coils and furnace coils.
$ Information
is specific to 25HNA6 and 25HNA9 models.
Pu ron
the
environmenta
ly
sould
r eldge_ant
Idealt_rniditf_
A_{ stane_rd 21012_0
Un_r_ _e_t Pumps
ISO 9001:2000
A
C
US
__kThinks.
Heats. Saves.
Ready for
use in a Hybrid
Heat ® Duel
Fuel system.
meet Energy
Star@ criteria for energy efficiency
when
matched
with appropriate
coil components.
However,
proper
refrigerant
charge
and proper
air flow are critical
to achieve
rated capacity
and efficiency.
Installation
of
this product
should
follow all manufacturing
refrigerant
charging
and air flow instructions.
Failure
to confirm
proper
charge
and air flow
may reduce
energy
efficiency
and
shorten
equipment
life.