Operating Ambient; Elevate Unit; Make Piping Connections - Carrier 25HNA6 Installation Instruction

Infinity series heat pump with puron refrigerant 2 to 5 nominal tons (sizes 24 to 60)
Hide thumbs Also See for 25HNA6:
Table of Contents

Advertisement

Operating
Ambient
The
minimum
outdoor
operating
ambient
in cooling
mode
is
55°F/12.78°C
without
low
ambient
cooling
enabled,
and
the
maximum
outdoor
operating
ambient
in
cooling
mode
is
125°F/51.67°C.
On
Infinity
communicating
systems
only
(for
both 25HNA6
and 25HNA9),
low ambient
cooling
is available
to
0°F/-17.78°C.
The
maximum
outdoor
operating
ambient
in heating
mode
is
66°F/18.89°C
on all models.
Elevate Unit
UNIT
OPERATION
HAZARD
Make Piping
Connections
PERSONAL
INJURY AND UNIT DAMAGE
HAZARD
Failure
to follow
this warning
could
result
in personal
injury or death.
Relieve
pressure
and recover
all refrigerant
before
system
repair or final unit disposal.
Use all service ports and open
all flow-control
devices,
including
solenoid
valves.
Failure
to follow
this caution
may
result
in equipment
damage
or improper
operation.
Do not allow water
and/or ice to build up in base pan.
Elevate
unit per local
climate
and code
requirements
to provide
clearance
above
estimated
snowfall
level
and
ensure
adequate
drainage
of unit.
UNIT
OPERATION
HAZARD
Failure
to follow
this caution
may
result
in equipment
damage
or improper
operation.
Locate
the
unit
in such
a way
that
it is stable
in all
circumstances
including
adverse
weather
conditions.
In Long-Line
Applications,
Install
Liquid-Line
Solenoid
Valve (LSV)
For refrigerant
piping
arrangements
with equivalent
lengths
greater
than 80 ft. (24.38
m) and/or when
elevation
difference
between
indoor
and outdoor
unit is greater
than ---20 ft. (---6.10
m), follow
all requirements
of the Long-Line
Guideline--Air
Conditioners
and Heat
Pumps
Using
Puron®
refrigerant.
If required
by
Long-Line
Guideline,
install LSV kit, part no. KHALS0401LLS,
specifically
designed
for Puron®
refrigerant
heat
pumps.
LSV
should be installed
within 2 ft. (0.61 m) of outdoor
unit with flow
arrow
pointing
toward
outdoor
unit.
Follow
the
Installation
Instructions
included
with accessory
kit.
IMPORTANT:
Flow arrow must point toward
outdoor
unit.
UNIT
DAMAGE
HAZARD
Failure
to follow
this caution
may
result
in
equipment
damage
or improper
operation.
Do not leave
system
open
to atmosphere
any longer
than
minimum
required
for installation.
POE oil in compressor
is
extremely
susceptible
to moisture
absorption.
Always
keep
ends of tubing sealed during
installation.
UNIT
DAMAGE
HAZARD
Failure
to follow
this caution
may
result
in equipment
damage
or improper
operation.
If ANY refrigerant
tubing
is buried,
provide
a 6 in. vertical
rise at service valve.
Refrigerant
tubing
lengths
up to 36 in.
(914.4
mm)
may
be
buried
without
further
special
consideration,
Do not bury
lines longer
than 36 in. (914,4
mm).
Outdoor
units may be connected
to indoor
section
using accessory
tubing
package
or field-supplied
refrigerant
grade tubing of correct
size and condition.
For tubing
requirements
beyond
80 ft. (24.38
m),
substantial
capacity
and
performance
losses
can
occur.
Following
the recommendations
in the Application
Guideline
and
Service
Manual-Residential
Split-System
Air
Conditioners
and
Heat
Pumps
Using
Puron®
Refrigerant
will reduce
these
losses.
Refer
to Table
1 for field tubing
diameters.
Refer
to Table 2 for
accessory
requirements.
Outdoor
Unit
Connected
to
Factory-Approved
Indoor
Unit
Outdoor
unit
contains
correct
system
refrigerant
charge
for
operation
with
factory-approved,
ARI-rated
indoor
unit
with
highest
sales
volume
when
connected
by 15 ft. (4.57
m) of
field-supplied
or factory-accessory
tubing,
and factory-supplied
filter drier. Check refrigerant
charge for maximum
efficiency.