DIP Switch Setting
MODBUS
convertor
address
SET5-1 SET5-2 SET5-3 SET5-4 SET4-1 SET4-2 SET4-3 SET4-4
177
●
○
●
178
●
○
●
179
●
○
●
180
●
○
●
181
●
○
●
182
●
○
●
183
●
○
●
184
●
○
●
185
●
○
●
186
●
○
●
187
●
○
●
188
●
○
●
189
●
○
●
190
●
○
●
191
●
○
●
192
●
●
○
193
●
●
○
194
●
●
○
195
●
●
○
196
●
●
○
197
●
●
○
198
●
●
○
199
●
●
○
200
●
●
○
201
●
●
○
202
●
●
○
203
●
●
○
204
●
●
○
205
●
●
○
206
●
●
○
207
●
●
○
208
●
●
○
209
●
●
○
210
●
●
○
211
●
●
○
212
●
●
○
213
●
●
○
214
●
●
○
215
●
●
○
216
●
●
○
217
●
●
○
218
●
●
○
219
●
●
○
220
●
●
○
221
●
●
○
222
●
●
○
223
●
●
○
224
●
●
●
225
●
●
●
226
●
●
●
227
●
●
●
228
●
●
●
229
●
●
●
230
●
●
●
231
●
●
●
232
●
●
●
233
●
●
●
234
●
●
●
235
●
●
●
236
●
●
●
237
●
●
●
238
●
●
●
239
●
●
●
240
●
●
●
241
●
●
●
242
●
●
●
243
●
●
●
244
●
●
●
245
●
●
●
246
●
●
●
247
●
●
●
●
○
ON:
/ OFF:
●
○
○
○
●
○
○
●
●
○
○
●
●
○
●
○
●
○
●
○
●
○
●
●
●
○
●
●
●
●
○
○
●
●
○
○
●
●
○
●
●
●
○
●
●
●
●
○
●
●
●
○
●
●
●
●
●
●
●
●
○
○
○
○
○
○
○
○
○
○
○
●
○
○
○
●
○
○
●
○
○
○
●
○
○
○
●
●
○
○
●
●
○
●
○
○
○
●
○
○
○
●
○
●
○
●
○
●
○
●
●
○
○
●
●
○
○
●
●
●
○
●
●
●
●
○
○
○
●
○
○
○
●
○
○
●
●
○
○
●
●
○
●
○
●
○
●
○
●
○
●
●
●
○
●
●
●
●
○
○
●
●
○
○
●
●
○
●
○
●
●
●
●
●
●
○
●
●
●
○
●
●
●
●
●
●
●
●
○
○
○
○
○
○
○
○
○
○
○
●
○
○
○
●
○
○
●
○
○
○
●
○
○
○
●
●
○
○
●
●
○
●
○
○
○
●
○
○
○
●
○
●
○
●
○
●
○
●
●
○
○
●
●
○
○
●
●
●
○
●
●
●
●
○
○
○
●
○
○
○
●
○
○
●
●
○
○
●
●
○
●
○
●
○
●
○
●
○
●
●
●
○
●
●
(: Factory setting)
(6) MODBUS communication setting: Baud rate setting (SET6-4)
ON: 19200bps
OFF: 9600bps (Default)
(7) MODBUS communication setting: Parity setting (SET6-3)
●
ON: odd
○
OFF: even (Default)
●
* When the STOP bit setting is "2bit," parity is set to "None" regardless
○
of the setting of this switch.
●
○
(8) MODBUS communication setting: Stop bit setting (SET6-2)
●
Stop bit can be set (1 bit or 2 bit).
○
ON: 2bit
●
OFF: 1bit (Default)
○
●
(9) MODBUS communication setting: MODBUS communication terminal
○
resistance (SET7-4)
●
MODBUS communication terminal resistance can be set (Valid or
○
invalid).
●
Terminal resistance: 120Ω
○
Set the terminal resistances as necessary.
●
For MODBUS system, terminal resistances are necessary at the both
○
ends of communication line. (Total 2 terminal resistances)
Set the terminal resistances at the both ends to be valid and set the
●
terminal resistances other than at the both ends to be invalid.
○
ON: Terminal resistance valid
●
OFF: Terminal resistance invalid (Default)
○
●
* The switches from (5) to (8) are read at the time of power-on. Even if
○
these switches are changed after power-on, the setting is not reflected.
●
○
(10) U nused SW
●
SET2-2, SET6-1, SET7-1 to 3: Not used
○
All Default settings: "OFF"
●
○
●
9. TURNING ON THE POWER
○
●
○
●
Check that the power supply voltage is within the specified range. If
the power supply voltage outside the specification is input, it will cause
○
trouble.
●
○
Recheck the wiring. Incorrect wiring will cause trouble.
●
(1) Check the wiring of MODBUS convertor.
○
(2) Check the wiring and switches of units connected to convertor before
●
tuning on the power.
○
●
(3) Check that the switches of MODBUS convertor are correct.
○
(4) Turn on the power for the MODBUS Convertor.
●
○
• The MODBUS Convertor is initialized for a period of approximately a few
●
seconds after the power is turned on.
○
LED1 (green), LED2 (orange), LED5 (green), and LED6 (orange) flash.
●
• After initial setting is completed, operation will be restarted automati-
○
cally. LED1 (green) and LED5 (green) light.
●
○
* MODBUS Convertor does not operate during initialization.
●
If an error occurs, the LED1, LED2, LED3, or LED5, LED6, LED7 lights
○
or flashes.
●
○
●
○
●
○
●
○
●
○
●
○
●
○
●
○
●
CAUTION
En-8