Temperature Probe; Heating Elements - Vulcan-Hart VC5ED Service Manual

Full size electric convection oven
Hide thumbs Also See for VC5ED:
Table of Contents

Advertisement

VC5ED FULL SIZE ELECTRIC CONVECTION OVEN - REMOVAL AND REPLACEMENT OF PARTS

TEMPERATURE PROBE

electrical power to the machine and
follow lockout / tagout procedures.
1.
Remove RIGHT SIDE PANEL.
NOTE: If right side - front panel is not accessible, this
component can be serviced by removing CONTROL
PANEL.
2.
Disconnect the probe leads (1, Fig. 9) from the
solid state temperature control.
Fig. 9
3.
Remove the racks from inside cavity.
4.
Remove the probe guard.
F45652 (0217)
Disconnect the
Page 8 of 31
Fig. 10
5.
Remove probe by pushing it through the oven
wall opening (2, Fig. 9) in control panel area.
6.
Reverse the procedure to install the replacement
probe.
7.
Adjust the temperature control. Refer to: SOLID
STATE TEMPERATURE CONTROL TEST .

HEATING ELEMENTS

electrical power to the machine and
follow lockout / tagout procedures.
1.
Remove RIGHT SIDE - REAR PANEL.
2.
Disconnect element wire connectors.
Fig. 11
3.
Remove racks from cavity.
4.
Remove FAN COVER.
Loosen element screws on side wall.
5.
Remove screws on back wall holding brackets.
Disconnect the