Component Panel Components; Temperature Probe - Vulcan-Hart VC5GD Service Manual

Full size gas convection oven
Table of Contents

Advertisement

FULL SIZE GAS CONVECTION OVEN - REMOVAL AND REPLACEMENT OF PARTS
Fig. 7
NOTE: Panel with standard controls shown.
COMPONENT PANEL
COMPONENTS
electrical power to the machine and
follow lockout / tagout procedures.
1.
Remove RIGHT SIDE PANEL.
NOTE: If right side panel is not accessible, this
component can be service by removing the
CONTROL PANEL.
2.
Disconnect the wire leads to component being
replaced.
3.
Remove the component.
4.
Reverse procedure to install component.
5.
Check oven for proper operation.
Disconnect the
Page 7 of 35

TEMPERATURE PROBE

electrical power to the machine and
follow lockout / tagout procedures.
1.
Remove RIGHT SIDE PANEL.
NOTE: If right side - front panel is not accessible, this
component can be serviced by removing CONTROL
PANEL.
2.
Disconnect the probe leads (1, Fig. 8) from the
solid state temperature control.
Fig. 8
3.
Remove the racks from inside cavity.
4.
Remove the probe guard.
Disconnect the
F45598 (0616)