Omron E3X-NH Manual page 6

High-precision fiber-optic amplifier
Table of Contents

Advertisement

E3X-NH
If teaching is not stable:
The threshold indicator (red) will flash. The built-in buzzer will
beep 3 times.
Change the position of the object and the sensing distance
that has been set and repeat the process.
Through-beam Model
Light is received.
Diffuse Model
3. Set the mode selector to RUN. Be sure that the middle
threshold indicator is lit. The threshold will be set to a 50%
value.
Hold set button down
for 0.5 to 2.5 s
Diffuse Model
Mark
Base
One-point Teach Mode
1. Set the mode selector to TEACH.
Press the SET button once without a target object in the
sensing area. Be sure that all the threshold indicators (red)
are lit. The built-in buzzer will beep once when the threshold
indicators are lit.
2. Set the mode selector to RUN. The threshold is set automati-
cally.
3. The Sensor will automatically compensate for environmental
changes.
E3X-NH
Press once for 0.5 to 2.5 s
7

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

E3x-nh11E3x-nh41E3x-nh21E3x-nh51

Table of Contents