Wiring Diagrams; Indoor Units - Daikin FTKS20CVMB Service Manual

Inverter pair wall mounted type c-series
Hide thumbs Also See for FTKS20CVMB:
Table of Contents

Advertisement

SiBE04-401

2. Wiring Diagrams

2.1

Indoor Units

FTK(X)S 20/25/35 CVMB(9)(8), ATK(X)S 20/25/35 CVMB(9)
PCB3
S36
S35
INTELLIGENT-
EYE SENSOR
PCB2
S27
S26
LED1
LED2
LED3
S21
H1P
H2P
H3P
S1W
SIGNAL
RECEIVER
S32
R1T
R2T
WIRELESS
REMOTE
CONTROLLER
FTN20/25/35CVMB9, FTYN20/25/35CVMB9
PCB2
S27
S26
LED1
LED2
LED3
S21
H1P
H2P
H3P
S1W
SIGNAL
RECEIVER
S32
R1T
R2T
WIRELESS
REMOTE
CONTROLLER
Appendix
PCB1
(
TERMINAL FOR
)
CENTRALIZED CONTROL
S1
S7
M
S6
1~
M
indoor
M1S
:
PROTECTIVE EARTH
C70 :
RUNNING CAPACITOR
Fu
:
FUSE
PCB1
(
)
TERMINAL FOR
CENTRALIZED CONTROL
S1
S1
S7
M
S6
1~
M
indoor
M1S
: PROTECTIVE EARTH
C70 : RUNNING CAPACITOR
FU : FUSE
H1
Fu
3.15A
H2
C70
H3
TRANSMISSION
CIRCUIT
140˚C
M1F
H1P~H3P
:
PILOT LAMP
M1F
:
FAN MOTOR
M1S
:
SWING MOTOR
PCB1~PCB3
:
PRINTED CIRCUIT BOARD
R1T~R2T
:
THERMISTOR
S1~S36
:
CONNECTOR
S1W
:
OPERATION SWITCH
X1M
:
TERMINAL STRIP
H1
Fu
3.15A
H2
C70
H3
TRANSMISSION
CIRCUIT
140˚C
H1P~H3P
M1F
M1F
M1S
PCB1~PCB2 : PRINTED CIRCUIT BOARD
R1T~R2T
S1~S32
S1W
X1M

Wiring Diagrams

X1M
BLK
1
WHT
2
RED
3
GRN
/ YLW
FIELD WIRING.
CAUTION
NOTE THAT OPERATION WILL
RESTART AUTOMATICALLY IF
THE MAIN POWER SUPPLY IS
TURNED OFF AND THEN BACK
ON AGAIN.
X1M
BLK
1
WHT
2
RED
3
GRN
/ YLW
FIELD
CAUTION
NOTE THAT OPERATION WILL
RESTART AUTOMATICALLY IF
THE MAIN POWER SUPPLY IS
TURNED OFF AND THEN BACK
ON AGAIN.
: PILOT LAMP
: FAN MOTOR
: SWING MOTOR
: THERMISTOR
: CONNECTOR
: OPERATION SWITCH
: TERMINAL STRIP
1
2
3
outdoor
C:3D033599C
1
2
3
outdoor
WIRING.
C:3D038710A