Service Modes, Error Codes, and Fault Finding
Log the appropriate error and
set stand-by flag in NVM
Redefine wake up reasons for protection
state and transfer to stand-by µP.
Switch off LCD lamp supply
Wait 250ms (min. = 200ms)
Switch off LVDS signal
Switch off 12V LCD supply within a time frame
of min. 0.5ms to max. 50ms after LVDS switch
Ask stand-by µP to enter protection state
Switch Viper in reset state
Switch the NVM reset line HIGH.
Disable all supply related protections and switch off
the +2V5, +3V3 DC/DC converter.
switch off the remaining DC/DC converters
Switch OFF all supplies by switching HIGH the POD-
MODE and the ON-MODE I/O lines.
Flash LED in order to indicate
protection state*. (see FRS)
Protection
Figure 5-19 "Protection" flowchart
BJ2.4U/BJ2.5U PA
MP
off.
Wait 10ms
Wait 5ms
(*): This can be the standby LED or the ON LED
depending on the availability in the set under
discussion.