EN 12
4.
BJ2.4U/BJ2.5U PA
4.3.12 Now the AmbiLight lamp units can be removed from the frame.
Each of them is fixed with four T10 parker screws: two on the
inside and two on the outside of the frame.
4.3.13 LED Panel
1. After the AmbiLight diffusor frame has been removed, the
LED Panel is accessible.
2. Remove the T10 mounting screws that hold the panel.
3. Take out the panel.
When defective, replace the whole unit. Reconnect the earth-
cable during re-assembly.
4.3.14 Plasma Display Panel / Glass Plate
1
1
1
1
1
1
1
1
1
1
1
Figure 4-18 PDP Panel removal -1-
Mechanical Instructions
Figure 4-17 AmbiLight diffusor frame lift
1
1
1
1
1
3
1
1
2
1
1
1
1
1
1
1
G_15930_082.eps
190606
3 10
9
12
11
8
9
6
9
12 9
7
5
3 10
Figure 4-19 PDP Panel removal -2-
1. Remove the key control unit.
2. Remove the loudspeaker compartment by removing
screws [1]; see figure "PDP Panel removal -1-" for details.
3. Unplug connectors 1M36 and 1H01 from the side I/O panel
[2].
4. Unplug connectors 1M09 and 1M59 from the right
AmbiLight inverter panel [3].
5. Unplug connectors [4] from the SDI PDP power supply
panel. See figure "PDP Panel removal -2-" for details.
6. Carefully unplug LVDS connector [5] from the SSB.
7. Remove screw [6].
8. Remove LED panel [7].
9. Remove screw [8] from the earth tab.
10. Remove screws [9].
11. Gently lift the shielding with the SSB from the frame.
G_15960_104.eps
070306
3 10
12
9
4
11
9
12
9
9
3 10
G_15930_083.eps
190606