Electromagnetic Compatibility and Immunity
Cisco Systems Mechanical Environmental Design and Qualification Guideline
(ENG-3396, Rev. 7).
European Telecommunication Standards Institute (ETSI) ETS 300 386-1 (December 1994).
Details on how each standard applies in this Cisco product appear in Table A-3.
Table A-3
Category
U.S.A EMC
Japan EMC
Australia EMC
CE M mark
(EMC and immunity)
NEBS
(EMC and immunity)
EDVT
MDVT
The levels for the mandatory CE mark immunity tests are:
For IEC 1000-4-2 (ESD), the test level is 4.
For IEC 1000-4-3 (RS), the test level is 3.
For IEC 1000-4-4 (EFT), the test level is 4.
For IEC 1000-4-5 (Surge), the test level is 3.
A-4
Cisco MGX 8850 Installation and Configuration, Release 1.1.10, Part Number 78-6186-03
Electromagnetic Compatibility and Immunity
AC-Powered (220 VAC
FCC Part 15, Class A
Austel 3548 Class A
VCCI Class A
EMC: EN 55022 Class A
Immunity:
• EN 50082-1 (generic immunity)
• EN 61000-4-2 through -5 (mandatory)
• EN 61000-4-6 through -13 (not
mandatory)
not applicable
Cisco Systems: Electronic Design
Validation Test (EDVT) Plan
ABC-123, Rev. A, dated 1/29/1996
Cisco Systems: Mechanical
Environmental Design and Qualification
Guideline, ENG-3398, Rev. 7.
DC-Powered (-48V)
not applicable
not applicable
not applicable
not applicable
EMC:
GR-1089-CORE Class A (radiated
and magnetic fields) and line
conductance.
Immunity:
GR-1089-CORE ESD (8 KV contact)
RS (10 V/meter)
CS (clause 3.3.3)
European Telecom Standards (ETSI)
for Surge: ETSI 300 386-1, DC
power leads only
(200 VAC–1000 VAC)
Cisco Systems: Electronic Design
Validation Test (EDVT) Plan
ABC-123, Rev. A, 1/29/1996—DC
power cycling portions only.
NEBS requirements, physical:
(GR-63-CORE, Issue 1, October,
1995). See mandatory CE mark
immunity tests in forthcoming list.