Maintaining and Troubleshooting the HP ProLiant DL360 G9 Server
About this task
Follow the steps below to replace one of these drives:
• DL360/380G9 300GB 10K SAS 2.5" HDD
• DL360/380G9 300GB 15K SAS 2.5" HDD
• DL360/380G9 600GB 10K SAS 2.5" HDD
• DL360/380G9 900GB 10K SAS 2.5" HDD
• DL360/380G9 1.2TB 10K SAS 2.5" HDD
• DL360/380G9 200GB SATA 2.5" SSD
Procedure
1. Remove the drive.
a. Push button to release locking latch. (#1 in the following image)
b. Pull on unlocked latch to remove HDD/SSD. (#2 in the following image)
Drives are hot-swappable so power down of server is not recommended. However, only one
drive must be replaced at a time until RAID array rebuild is complete.
2. Replace the drive.
a. Insert HDD/SSD into empty drive slot.
b. Secure HDD/SSD by closing the latch.
c. Refer to the Hard Drive LED table for the drive rebuild status.
d. Check using Avaya application tools for RAID status if available.
Related links
Hard disk drive problems

Power supply problems

Symptoms
Some possible symptoms indicating power supply problems are:
• The server does not power on.
November 2015
on page 16
Maintaining and Troubleshooting the HP ProLiant DL360 G9 Server
Comments on this document? infodev@avaya.com