HP ProLiant DL360 G9 Maintaining And Troubleshooting page 15

Hide thumbs Also See for ProLiant DL360 G9:
Table of Contents

Advertisement

Ite
LED
m
1
Locate
2
Activity ring
3
Do not remove Solid white Do not remove the drive.
4
Drive status
November 2015
Status
Definition
Solid blue
The drive is being identified by a
host application
Flashing
The drive carrier firmware is being
blue
updated or requires an update
Rotating
Drive activity
green
Off
No drive activity
Removing the drive causes one or
more of the logical drives to fail.
Off
Removing the drive does not cause
a logical drive to fail.
Solid
The drive is a member of one or
green
more logical drives
Flashing
The drive is rebuilding or
green
performing a RAID migration, stripe
size migrations, capacity
expansion, or logical drive
extension, or is erasing.
Flashing
The drive is a member of one or
amber/
more logical drives and predicts
green
the drive will fail.
Maintaining and Troubleshooting the HP ProLiant DL360 G9 Server
Comments on this document? infodev@avaya.com
External Maintenance Field Replaceable Units
Avaya recommendations and
information
This is normal operation if
application supports this feature or
if disk array is being created/
selected.
Check support.avaya.com for HP
DL360 G9 firmware updates. View
release notes for Avaya firmware
update inclusions for HDD update.
This is normal operation and
indicates that the drive is currently
operating as part of the RAID
array.
This indicates that the drive may
currently have no activity or is not
part of the RAID array.
This indicates that the RAID array
is operating in degraded mode
because one of the drives in the
array has failed or is currently
rebuilding. Removing a drive in this
state will destroy the logical drive
array. If the array is currently
rebuilding this status will clear
when the new replacement drive
has rebuilt. Rebuild can take from
20 minutes up to 2 hours
depending on the size of drive and
activity of the system.
If an active drive is removed, the
other drives that are part of the
array will indicate a status of "do
not remove".
This indicates normal operation.
A newly inserted replacement drive
should start this LED pattern within
10-15 seconds of insertion to
indicate a rebuild of the logical
drive. If action does not start,
unplugging and reinserting new
drive can be performed.
This signature indicates future
failure and drive should be
replaced asap.
Table continues...
15

Advertisement

Table of Contents
loading

Table of Contents