HP ProLiant DL360 G9 Maintaining And Troubleshooting page 21

Hide thumbs Also See for ProLiant DL360 G9:
Table of Contents

Advertisement

• DL360/380G9 800 W AC PWR SUP
• DL360/380G9 800 W DC PWR SUP
Procedure
1. If system does not have redundant power, shut down the server according to Avaya
application procedures. Server might already be down because of failed power supply. If
server power is redundant, proceed to step 2.
• If server does not power down according to normal shutdown procedures, press and
release the Power On/Standby button. This method initiates a controlled shutdown of
applications and the OS before the server enters standby mode.
• Press and hold the Power On/Standby button for more than 4 seconds to force the server
to enter standby mode. This method forces the server to enter standby mode without
properly exiting applications and the OS. If an application stops responding, you can use
this method to force a shutdown, but be aware that file corruption could occur using this
method.
2. Replace failed power supply.
a. Press tab (1 in the following figure).
b. Pull supply out (2 in the following figure).
c. Install new supply.
Figure 1: Replacing power supply
3. If disconnected, connect the power cables to the power supply.
4. If powered down, power up the server.
November 2015
Maintaining and Troubleshooting the HP ProLiant DL360 G9 Server
Comments on this document? infodev@avaya.com
External Maintenance Field Replaceable Units
21

Advertisement

Table of Contents
loading

Table of Contents