CAUTION
Remove carton carefully. Wear gloves to protect
against sharp edges.
LIST OF MATERIALS
Parts included in your hood
3 1/4" x 10" Rectangular vent damper
•
2 - Grease filters
•
Use and Care / Installation Manual
•
Mounting screw kit
•
2 - 0.49 * 5.0 cm mounting screws
4 - 0.50 * 1.9 cm mounting screws
6 - 0.40 * 0.8 cm rectangular vent damper screws
2 - plastic wall anchores
Tools/Materials required
Wire nuts
•
Metal duct length to suit installation
•
Vent clamps/duct tape as required
•
UL listed or CSA approved ½" strain relief
•
Remove the protective film covering the product before
•
putting into operation.
5/64" drill bit for cabinet pilot holes
•
Pencil
•
Wire cutter / stripper
•
Measuring tape
•
Caulking gun and weatherproof caulking compound
•
Flat-blade screwdriver
•
Phillips screwdriver
•
Saber or keyhole saw
•
Safety glasses
•
Gloves
•
For cabinets with recessed bottoms:
Two - 2" (5.1 cm) wide filler strips. Length and
•
thickness determined by recess dimensions.
Four flat head wood screws or machine screws
•
with washers and nuts (to attach filler strips).
NOTE
If configuring for recirculation venting, range hood
model FHWC3050RS uses recirculation kit
FHWRKT30RS and if using range hood model
FHWC3650RS recirculation kit FHWRKT36RS
B
would be used.
LIST OF MATERIALS
ELECTRICAL REQUIREMENTS
Observe all governing codes and ordinances.
Ensure that the electrical installation is adequate and in
conformance with National Electrical Code, ANSI/NFPA
70 (latest edition), or CSA Standards C22.1-94, Canadian
Electrical Code, Part 1 and C22.2 No. 0-M91 (latest edi-
tion) and all local codes and ordinances.
If codes permit and a separate ground wire is used, it is
recommended that a qualified electrician determine that
the ground path is adequate.
A copy of the above code standards can be obtained
from:
National Fire Protection Association
One Batterymarch Park
Quincy, MA 02269
CSA International
8501 East Pleasant Valley Road
Cleveland, OH 44131-5575
A 120 volt, 60 Hz., AC only, 15-amp, fused electrical
•
circuit is required.
If the house has aluminum wiring, follow the
•
procedure below:
1.
Connect a section of solid copper wire to the
pigtail leads.
.
Connect the aluminum wiring to the added
section of copper wire using special conectors
and/or tools designed and UL listed
for joining copper to aluminum.
Follow the electrical connector manufacturer's recom-
mended procedure. Aluminum/copper connection must
conform with local codes and industry accepted wiring
practices.
Wire sizes and connections must conform with
•
the rating of the appliance as specified on the
model/serial rating plate.
The model/serial plate is located on the left side of
the range hood.
Wire sizes must conform to the requirements of
•
the National Electrical Code, ANSI/NFPA 70 (la
est edition), or CSA Standards C22. 1-94, Canad
Electrical Code, Part 1 and C22.2 No. 0-M91
(latest edition) and all local codes and ordinances.
an
EN-