Summary of Contents for Frigidaire FHWC3025MB

  • Page 1 USA 1-800-944-9044 Canada 1-800-265-8352 www.frigidaire.com www.frigidaire.ca LI30KC / 316902495 May/13...
  • Page 2: Table Of Contents

    Install Range Hood (Ducted version) ..... 10 Make Electrical Connection ........12 Installing Range Hood (Recirculating version) ..10 Visit the Frigidaire web site at www.frigidaire.com Range Hood Use ..........13 Before you call for service, there are a few things you can Range Hood Care ..........
  • Page 3: Important Safety Instructions

    IMPORTANT SAFETY INSTRUCTIONS Read all instructions before using this appliance. Save these instructions for future references WARNING Approved for residential appliances TO REDUCE THE RISK OF FIRE, ELECTRIC For residential use only SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: Do not attempt to install or operate your appliance until Use this unit only in the manner intended by the you have read the safety precautions in this manual.
  • Page 4 IMPORTANT SAFETY INSTRUCTIONS WARNING WARNING To Reduce The Risk Of Fire Or Electric Shock, Do TO REDUCE THE RISK OF INJURY TO PERSONS, IN THE EVENT OF A RANGE TOP GREASE FIRE, Speed Control Device. OBSERVE THE FOLLOWING: SMOTHER FLAMES sheet, or other metal tray, then turn off the gas WARNING burner or the electric element.
  • Page 5: List Of Materials

    LIST OF MATERIALS LIST OF MATERIALS ELECTRICAL REQUIREMENTS Parts included in your hood Observe all governing codes and ordinances. • Ensure that the electrical installation is adequate and in • 3¼ conformance with National Electrical Code, ANSI/NFPA system. 70 (latest edition), or CSA Standards C22.1-94, Canadian NOTE: An optional 7”...
  • Page 6: Location Requirements

    LOCATION REQUIREMENTS Cabinet Dimensions IMPORTANT Observe all governing codes and ordinances. • It is the installer’s responsibility to comply with rating plate. The model/serial rating plate is located inside the range hood on the left side (See page 2 for location). Range hood location should be away from strong draft areas, such as windows, doors and strong heating vents.
  • Page 7: Venting Requirements

    VENTING REQUIREMENTS • Vent system must terminate to the outdoors. Roof Venting Wall Venting • Do not terminate the vent system into an attic or other enclosed area. • Do not use a 4” (10.2 cm) laundry-type wall cap. • Use a 3¼...
  • Page 8: Prepare The Location

    VENTING REQUIREMENTS PREPARE THE LOCATION 3¼ Vent Piece NOTE 3¼ 90° elbow (1.5 m) Before making cutouts, make sure there is proper clearance within the ceiling or wall. 3¼ flat elbow (3.7 m) Disconnect power. Place covering over that surface. 3¼...
  • Page 9 PREPARE THE LOCATION To wire through top: Mark a line distance (A) from the right of the 25.4 cm) Rectangular Vent System centerline on the underside of the cabinet. Mark the point on this line that is ” (2.2 cm) from back wall. Roof Venting Drill a 1¼”...
  • Page 10: Install Range Hood (Ducted Version)

    PREPARE THE LOCATION Install Vent System cm) Rectangular Vent Transition to Round Vent Install vent through the vent opening in upper cabinet or wall. Complete venting system according to the Roof Venting selected venting method. See “Venting Requirements” To make a circular vent opening on the underside of the section.
  • Page 11 INSTALLING THE HOOD ” (3 mm) drill bit and drill 4 pilot holes as shown. Power Supply Cable Installation NOTE: Make the drill holes on the thin area of the slot. For direct wire installations, run the home power supply cable according to the National Electric Code or CSA standards and local codes and ordinances.
  • Page 12: Make Electrical Connection

    INSTALLING THE HOOD MAKE ELECTRICAL CONNECTION INSTALL RANGE HOOD (Recirculating version) WARNING Lift the range hood up under cabinet and determine Electrical Shock Hazard Disconnect power before servicing. the underside of cabinet the location of the 4 keyhole Replace all parts and panels before operating. mounting slots on the range hood (See slots Failure to do so can result in death or electrical shock.
  • Page 13: Range Hood Use

    RANGE HOOD USE RANGE HOOD USE Remove the power supply knockout from the top or rear of the vent hood (depending on the incoming The range hood is designed to remove smoke, cooking location of your home power supply cable) and vapors and odors from the cooktop area.
  • Page 14: Range Hood Care

    RANGE HOOD CARE Cleaning WARNING retainer. To Reduce The Risk Of Fire Or Electrical shock disconnect from power supply before cleaning. a mild detergent. Rinse well and shake to dry. Or place in upper rack of dishwasher IMPORTANT A. Filter screw to clean.
  • Page 15: Troubleshooting

    TROUBLESHOOTING Problem Possible Causes Solutions After installation, 1. The power line and the cable locking 1. Check the power connection with the unit is the unit doesn’t connector is not connecting properly. connected properly. work. 2. The wires from the switches are disconnected 2.
  • Page 16: Warranty Information

    Warranty Your appliance is covered by a one year limited warranty. For one year from your original date of purchase, Electrolux will repair or replace any parts of this appliance that prove to be defective in materials or workmanship when such appliance is installed, used, and maintained in accordance with the provided instructions.