10. Functions explained
d17
Preset program selection
d18
Heat/Cool Mode Selection
d19
Cooling Blocked
d20
Actuators loading selection
for different temperature
compensation.
11. Cooling Blocked
When When the thermostat is set on Cooling Disabled (d19-->1) it will block the cooling
function for single rooms until the device will receive the heating command. During the
periods of cooling blocked no special indicator will be displayed on the LCD screen. Ice flake
will also be turned off.
Note: d19 will be available only if d18 is set on 1 (Heat/Cool Mode selection Connected).
24
AHTR5024 Instruction Manual
Select one of these 5 default programs. Once selected,
default program will overwrite present program.
1-5
Selected default program can be edited by the user in
the User Setting Mode.
0 or 1
0: No connection 1: Connection
0: Cooling allowed
0 or 1
1: Cooling disabled
1: x 1 actuator loading
1 to 5
3: x 3 actuators loading 4: x 4 actuators loading
5: x 5 actuators loading
2: x 2 actuators loading
1
0
0
1