Salus AHTR5024 Installer Manual page 22

Advertisement

10. Functions explained
D setting function
dxx
d00
Select oC/oF
d01
Heating Control
d02
Room temp. offset
d03
OUT sensor probe (S1/S2)
Air sensor or Floor sensor
d04
d05
Cooling Control
d07
Valve Protection
d08
Frost Setpoint
22
AHTR5024 Instruction Manual
Parameter/
Definition
Values
0
1
0
PWM (Pulse-width modulation)
1
ON-OFF: 0.5C (± 0.25ºC)
2
ON-OFF: 1.0C (± 0.5ºC)
-3.0oC to + 3.0oC
Offset room temp measuring error (in 0.5ºC)
0
Out sensor probe not connected
1
Out sensor probe connected
0
A: if d03 = 0, IN sensor controls Tr
A: if d03 = 1, IN disabled and OUT controls Tr
1
F: if d03 = 0, IN sensor controls Tr
F: if d03 = 1, IN disabled and OUT controls Tr Floor Protection
1
ON-OFF: 0.5ºC (± 0.25ºC)
2
ON-OFF: 1.0ºC (± 0.5ºC)
0/1
0 = VP disabled 1 = Enable
5ºC - 17ºC
Select oC
Select oF
Default
value
0
0
0.0ºC
0
0
2
1
5.0ºC