7.13 HYDRAULIC FILTER _______________________________________________________

The hydraulic system is protected by a 10 micron return
line filter. Flow though the filters is monitored during
operation. When pressure drop across the filters is too
high the hydraulic oil filter warning light will come on. To
ensure continued protection to the hydraulic system,
replace filter as soon as possible after light comes on.
NOTICE
During cold weather the warning light may come on
until oil has warmed up to operating temperature. Wait
until oil has warmed up and light goes out before
operating mower.

7.14 ELECTRICAL SYSTEM _____________________________________________________

!
CAUTION
Always turn the ignition switch OFF and remove the
negative battery cable (BLACK) before inspecting or
working on the electrical system.
General precautions that can be taken to reduce
electrical problems are listed below.
1. Make certain all terminals and connections are clean
and properly secured.
2. Check the interlock system, fuses and circuit
breakers regularly.
If the interlock does not function properly and the
problem cannot be corrected, contact an authorized
Jacobsen Dealer.
3. Keep the wire harness and all individual wires away
from moving parts to prevent damage.
4. Make sure the seat switch harness is connected to
the main wire harness.
5. Check the battery and battery charging circuit.
6. Do not wash or pressure spray around electrical
connections and components.
The electrical system is monitored and controlled by the
electronic controller (C) located behind the operator's
area. The controller is equipped with two banks of LED's
which can be used when troubleshooting the electrical
system. See Section 9.2.
To replace hydraulic filter:
1. Remove the old filter.
2. Install new filter. Hand tighten only.
3. Operate engine at idle speed with hydraulic system
in Neutral for five minutes. The oil level alarm may
sound during this time.
4. Check hydraulic oil level in reservoir and fill to full
mark on dipstick.
NOTICE
For factory assistance with troubleshooting controller
problems, please note the controller hardware
revision and software version located on the lower
right corner of the controller. Controllers with equal or
greater revision levels will be backward compatible.
Circuits are protected by a circuit breaker, fuses and
relays mounted on or near the controller.
CIRCUIT BREAKER
CB1 50 A CIRCUIT BREAKER
FUSES
F1 20 A ALTERNATOR, GAUGES, SWITCHES
F2 20 A LIGHTS
RELAYS
K1