Toyotomi CCT 50HINVi Service Manual page 42

Table of Contents

Advertisement

2.1.5 Icon explanation on indoor display board (Compact cassette).
2.2 Indoor unit malfunction
NO.
Malfunction
Communication malfunction between indoor
1
and outdoor units.
Open or short circuit of T1 temperature
2
sensor
Open or short circuit of T2 temperature
3
sensor
Open or short circuit of T2B temperature
4
sensor
5
Full-water malfunction
6
Indoor EEPROM malfunction
7
Outdoor unit malfunction
8
Indoor fan speed is out of control
Communication malfunction between main
9
PCB and up-down panel PCB
10
Up-down panel malfunction
11
Up-down panel is not closed
Communication malfunction between master
12
unit and slave unit
13
Other malfunction of master unit or slave unit
Electrical Control System
Defrosting
lamp
X
X
X
X
X
X
X
X
O (on)
X(off)
(flash at 5Hz)
Alarm
Running lamp
lamp
X
X
X
X
X
X
X
X
X
X
X
X
X
(flash at 0.5Hz)
Troubleshooting
Timer
Display(digital
lamp
tube)
E1
X
E2
X
E3
X
E4
X
EE
X
E7
X
Ed
X
E8
X
F0
F1
O
F2
F3
X
F4
105