SECTION 3
OPERATING INSTRUCTIONS
Operation
Normal Rated
Performance Cruise
(75% Rated)
Economy Cruise
(65% Rated)
* - At Bayonet Location – For maximum service life of the engine, maintain cylinder head temperatures
between 150°F (65°C) and 400°F (204°C) during continuous operation.
Operation
Normal Rated
Performance Cruise
(75% Rated)
Economy Cruise
(65% Rated)
Operation
Take-Off
Normal Rated
Performance Cruise
(75% Rated)
Economy Cruise
(65% Rated)
Operation
Take-Off
Normal Rated
Performance Cruise
(75% Rated)
Economy Cruise
(65% Rated)
3-8
OPERATING CONDITIONS (CONT.)
O-235-F, -G, -J
RPM
HP
2800
125
2500
94
2400
81
O-235-K, -L, -M
RPM
HP
2800
118
2500
89
2400
77
O-235-K2C
RPM
HP
2800
118
2700
115
2425
86
2300
75
O-235-H Series
RPM
HP
2800
115
2600
108
2350
81
2250
70
LYCOMING OPERATOR'S MANUAL
O-235 AND O-290 SERIES
Fuel
Max.
Cons.
Oil Cons.
Gal./Hr.
Qts./Hr.
10.7
0.56
7.3
0.31
5.8
0.27
Fuel
Max.
Cons.
Oil Cons.
Gal./Hr.
Qts./Hr.
9.5
0.39
6.7
0.30
5.8
0.27
Fuel
Max.
Cons.
Oil Cons.
Gal./Hr.
Qts./Hr.
----
----
9.2
0.38
6.4
0.29
5.6
0.25
Fuel
Max.
Cons.
Oil Cons.
Gal./Hr.
Qts./Hr.
----
----
10.7
0.36
7.3
0.27
5.8
0.23
*Max.
Cyl. Head
Temp.
500°F (260°C)
500°F (260°C)
500°F (260°C)
Max.
Cyl. Head
Temp.
500°F (260°C)
500°F (260°C)
500°F (260°C)
Max.
Cyl. Head
Temp.
500°F (260°C)
500°F (260°C)
500°F (260°C)
500°F (260°C)
Max.
Cyl. Head
Temp.
500°F (260°C)
500°F (260°C)
500°F (260°C)
500°F (260°C)