Operation; Master 200 Solid State Control With; Electromechanical Timer; In Off Mode - Garland Master Series Installation, Operation And Maintenance Manual

Full-size gas convection ovens - energy star
Table of Contents

Advertisement

OPERATION

Master 200 Solid State Control With

Electromechanical Timer

In Off Mode

When the oven is off , there are no lights or indicators.

Start Up

Press the Cook/Off /Cool Down rocker switch to the "Cook"
position. The green lamp will light indicating the oven is
powered in cook mode.
The oven will begin to heat to the temperature set on the
thermostat dial. The amber lamp will light indicating the heat
is active. As the heat cycles on and off to maintain the set
temperature this light will go on and off accordingly.
The door must be closed for the oven to operate in cook
mode. Opening the door will cause the heat to stop. The
motor and fan will shut off . This is a safety feature.

Fan Speed

The fan speed can be either high (1725RPM) or (1150 RPM).
The fan speed is controlled by the left rocker switch marked
high and low.

Lights

The oven lights are activated by pressing the light switch on
the control panel. This is a momentary switch and the lights
will stay lit as long as this button is held in the on position.
Lights will work whenever there is electrical power connected
to the oven.

Cool Down

Pressing the Cook/Off /Cool Down rocker switch to the Cool
Down position activates the fan and motor to cool the oven
cavity. The door must be open slightly for the fan and motor
to start. The heat is not active in this mode.
Optimal cool down will be achieved with the door open
slightly. Opening the door too far will shut the fan and motor
off . This is a patented safety feature.
Pressing the button to the OFF position cancels the cool
down and turns the oven off .

Temperature

The temperature range is from 150°F to 500°F (66°C to 250°C)
is controlled by rotating the temperature dial and aligning
the indicator to the desired temperature.

Timer

The timer is set by rotating the dial clockwise aligning the
indicator to the desired time cycle. The timer will count down
from 2 minutes to 60 minutes. At the end of the timing cycle
the buzzer will sound. The buzzer is turned off by rotating the
dial counter-clockwise to the off position as shown on the
control panel. (NOTE: The timer does not control heating. )