FOR YOUR SAFETY:
DO NOT STORE OR USE GASOLINE
OR OTHER FLAMMABLE VAPORS OR
LIQUIDS IN THE VICINITY OF
THIS OR ANY OTHER
IMPROPER INSTALLATION, ADJUSTMENT,
ALTERATION, SERVICE OR MAINTENANCE
CAN CAUSE PROPERTY DAMAGE, INJURY,
OR DEATH. READ THE INSTALLATION,
OPERATING AND MAINTENANCE
INSTRUCTIONS THOROUGHLY
BEFORE INSTALLING OR
SERVICING THIS EQUIPMENT
Users are cautioned that maintenance and repairs must be performed by a Garland authorized service agent
using genuine Garland replacement parts . Garland will have no obligation with respect to any product that has been
improperly installed, adjusted, operated or not maintained in accordance with national and local codes or installation
instructions provided with the product, or any product that has its serial number defaced, obliterated or removed,
or which has been modified or repaired using unauthorized parts or by unauthorized service agents .
For a list of authorized service agents, please refer to the Garland web site at http://www .garland-group .com .
The information contained herein, (including design and parts specifications), may be superseded and is subject
to change without notice .
GARLAND COMMERCIAL INDUSTRIES
185 East South Street
Freeland, Pennsylvania 1822
Phone: (570) 636-1000
Fax: (570) 636-3903
Part # 1382606 Rev 2 (12/07)
Part 1382606 Rev 2 (12/07)
APPLIANCE
WARNING:
GARLAND COMMERCIAL RANGES, LTD .
1177 Kamato Road, Mississauga, Ontario LW 1X
CANADA
Phone: 905-62-0260
Fax: 905-62-5669
PLEASE READ ALL SECTIONS OF THIS MANUAL
AND RETAIN FOR FUTURE REFERENCE .
THIS PRODUCT HAS BEEN CERTIFIED AS
COMMERCIAL COOKING EQUIPMENT AND
MUST BE INSTALLED BY PROFESSIONAL
PERSONNEL AS SPECIFIED .
IN THE COMMONWEALTH OF MASSACHUSETTS
THIS PRODUCT MUST BE INSTALLED BY A
LICENSED PLUMBER OR GAS FITTER . APPROVAL
NUMBER: G-1-07-05-28
For Your Safety:
Post in a prominent location, instructions to be
followed in the event the user smells gas . This
information shall be obtained by consulting
your local gas supplier .
Enodis UK LTD .
Swallowfi eld Way, Hayes, Middlesex UB3 1DQ ENGLAND
Telephone: 081-561-033
Fax: 081-88-001
© 2005 Garland Commercial Industries, Inc .
Page 1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MASTER SERIES and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Garland MASTER SERIES

  • Page 1: Filter Quick

    Users are cautioned that maintenance and repairs must be performed by a Garland authorized service agent using genuine Garland replacement parts . Garland will have no obligation with respect to any product that has been improperly installed, adjusted, operated or not maintained in accordance with national and local codes or installation instructions provided with the product, or any product that has its serial number defaced, obliterated or removed, or which has been modified or repaired using unauthorized parts or by unauthorized service agents .
  • Page 2 Page 2 Part #1382606 Rev 2 (12/07)
  • Page 3: Table Of Contents

    TABLE OF CONTENTS DIMENSIONS AND SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 INSTALLATION .
  • Page 4: Dimensions And Specifications

    DIMENSIONS AND SPECIFICATIONS 33-3/8" OPTIONAL [848mm] 1" OR 3/4" N.P.T. REAR 3" GAS INLET 31-1/2" 46-3/4" [76mm] [800mm] [1187mm] With "BG" BACKGUARD 40-1/4" 63-3/4" [1022mm] [1619mm] 1-1/4" N.P.T. 30-3/8" With "LPBG" With "DDBG" [32mm] [772mm] BACKGUARD BACKGUARD GAS INLET 33-7/8" [860mm] FRYER FILTER...
  • Page 5: Installation

    . commercial applications only . Garland / U .S . Range will not provide service, warranty, maintenance or support of any C . On the end units of the Filter/Fryer Battery use a pipe kind other than in commercial applications .
  • Page 6: Wire Interconnection

    INSTALLATION Continued FIGURE 1 FRYER FRYER FRYER FILTER FRYER FRYER FRYER FRYER FILTER FRYER 6 . Cap the extreme right and or left drain tube by installing FIGURE 3 the gasket 17 and cover 18 on the end of the drain tube . Clamp in place as shown in Fig .
  • Page 7: Operation

    30 minutes . do other tasks while filtering is in progress . As many as six 35 lb GARLAND gas fryers may be batteried together and The Filter Quick System revolves around two original manifolded to a single Filter Quick System .
  • Page 8: Cleaning And Maintenance

    CLEANING AND MAINTENANCE NEVER operate the fryer or the filter without shortening in The frypot should be cleaned periodically . This operation can the system . be combined with disposing of the used shortening . After the fryer has been empties, the frypot should be drained and The shortening should be filtered as often as needed .
  • Page 9: Trouble Shooting

    TROUBLE SHOOTING CORRECTIVE ACTION BY PROBLEM PROBABLE CAUSE CORRECTIVE ACTION SERVICEMAN Filter Heat Switch does not Unit unplugged Plug in cord set . Same glow Loose wire . None Replace wire Defective switch None Replace defective switch . Filter Heater will not heat Pan not in place .
  • Page 10: Parts List

    PARTS LIST PART NUMBER DESCRIPTION 1578600 Switch, Drain Valve 157600 Drain Valve 1/ In . 1581200 Micro Switch Bracket 1580900 Clamp, Drain Tube 8003123 Screw, Clamp 800120 Nut, clamp 1573800 Handle, Return Valve 1581300 Power Shower Single Vat 1578100 Valve, Oil Return 1578600 Micro Switch, Pump control 1578800...
  • Page 11: Wiring Diagram

    WIRING DIAGRAM Part 1382606 Rev 2 (12/07) Page 11...