  • Page 1 Product Training Content Installer Settings manual...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS SYSTEM SETTINGS INSTALLER SETTINGS Auto Changeover Default Settings Indoor Equipment Type/Stages Remote Sensor Initiate Installer Settings Outdoor Equipment Type/Stages 9-10 Cool Lockout Installer Setting Options Auto Allowed Time Between Fuel Types Programmable or Non-Programmable Cycles Per Hour Fahrenheit or Celcius Humidifier Smart Recovery...
  • Page 3: System Settings

    SYSTEM SETTINGS...
  • Page 4 SYSTEM SETTING DEFAULTS SYSTEM SETTINGS DEFAULT Indoor Equip Type FURNACE Indoor Equip Stages Outdoor Equip Type Outdoor Equip Stages Auto Allowed? Prog or Non-Prog PROG Fahrenheit or Celsius °F Smart Recovery Fan On with W Reversing Valve COOL Indoor Temp Offset 0°F Indoor HUM Offset Auto Changeover...
  • Page 5: Initiate Installer Settings

    INITIATE INSTALLER SETTINGS Off Mode Selected Press and Hold 5 Seconds DEFINITION DEPENDENCIES FUNCTION To invoke the “System Settings Screen” the end None Once the “System Settings Screen” is user must first navigate to the “Mode Screen” displayed, the end user has the option to and then ensure that the Mode is set to Off and “Up Swipe”...
  • Page 6: Installer Setting Options

    INSTALLER SETTING OPTIONS...
  • Page 7: Installer Settings

    INSTALLER SETTINGS...
  • Page 8 SETTINGS – INDOOR EQUIPMENT TYPE DEFINITION DEPENDENCIES FUNCTION Pressing the Indoor Equip Type field in None INDOOR EQUIPMENT — An indoor equipment type the “System Settings Screen” will invoke must be chosen so that an airflow source is the “Indoor Equip Type Screen” which available to the system operation.
  • Page 9 SETTINGS – INDOOR EQUIPMENT STAGES DEFINITION DEPENDENCIES FUNCTION Pressing the Indoor Equip Stages field in The option of “0” INDOOR INDOOR EQUIPMENT STAGES — The the “System Settings Screen” will invoke EQUIPMENT STAGES is only numbers of stages chosen defines the the “Indoor Equip Stages Screen”...
  • Page 10 SETTINGS – OUTDOOR EQUIPMENT TYPE DEFINITION DEPENDENCIES FUNCTION Pressing the Outdoor Equip Type field If NONE is chosen for the outdoor OUTDOOR EQUIPMENT — An in the “System Settings Screen” will equipment, then no cooling will be outdoor equipment type is not invoke the “Outdoor Equip Type available and the COOL MODE will be required to be chosen and result in...
  • Page 11: Outdoor Equipment Type/Stages

    SETTINGS – OUTDOOR EQUIPMENT STAGES DEFINITION DEPENDENCIES FUNCTION Pressing the Outdoor Equip Stages field in the “System The option of “0” The numbers of stages chosen Settings Screen” will invoke the “Outdoor Equip Stages OUTDOOR defines the number of HP or A/C Screen”...
  • Page 12 SETTINGS – AUTO ALLOWED? No= Disabled “Auto Mode” DEFINITION DEPENDENCIES FUNCTION Pressing the Auto Allowed? field in the The AUTO ALLOWED feature is The AUTO ALLOWED feature is used to “System Settings Screen” will invoke only available if both a heating enable and disable the ability of the AUTO the “Auto Allowed Screen”...
  • Page 13 SETTINGS – PROG OR NON-PROG DEFINITION DEPENDENCIES FUNCTION Pressing the PROG or If the NON-PROG Choosing the non-programmable mode for the thermostat allow the NON-PROG field in the functionality is chosen thermostat to run in a simplified mode that will satisfy heating or “System Settings then the PLAY/PAUSE cooling setpoints based on the setpoint value and mode chosen.
  • Page 14 SETTINGS – FAHRENHEIT OR CELSIUS DEFINITION DEPENDENCIES FUNCTION Pressing the Fahrenheit or Celsius field in the None This feature allows the thermostat temperatures to be “System Settings Screen” will invoke the displayed using either the Fahrenheit scale or the “Fahrenheit or Celsius Screen” which allows Celsius scale the thermostat to use either the Fahrenheit or Celsius scale to display temperature and...
  • Page 15 SETTINGS – SMART RECOVERY DEFINITION DEPENDENCIES FUNCTION Pressing the Smart Recovery The SMART The Smart Recovery feature transitions the conditioned field in the “System Settings RECOVERY feature is space from one programmable temperature period to the Screen” will invoke the “Smart only available if the next so that the conditioned space temperature matches the Recovery Screen”...
  • Page 16 SETTINGS – FAN ON WITH W DEFINITION DEPENDENCIES FUNCTION Pressing the Fan On with W field in the None The Fan On With W feature is used to supply a fan “System Settings Screen” will invoke the output demand as soon as a W1 or W2 output demand “Fan On with W Screen”...
  • Page 17 SETTINGS – REVERSING VALVE DEFINITION DEPENDENCIES FUNCTION Pressing the Reversing Valve field in the This functionality is This functionality defines whether the ON state of “System Settings Screen” will invoke the only used in the reversing valve is used for Heating or Cooling. “Reversing Valve Screen”...
  • Page 18 SETTINGS – INDOOR TEMP OFFSET DEFINITION DEPENDENCIES FUNCTION Pressing the Indoor Temp Offset field in the None This functionality offers the end user the “System Settings Screen” will invoke the convenience of matching the actual sensed “Indoor Temp Offset Screen” which will offset temperature to a different perceived temperature or the displayed thermostat room temperature a different temperature measuring device.
  • Page 19 SETTINGS – INDOOR HUM OFFSET DEFINITION DEPENDENCIES FUNCTION Pressing the Indoor HUM Offset field in the None This functionality offers the end user the “System Settings Screen” will invoke the convenience of matching the actual sensed “Indoor HUM Offset Screen” which will offset humidity to a different perceived humidity or a the displayed thermostat humidity reading different humidity measuring device.
  • Page 20 SETTINGS – AUTO CHANGEOVER DEFINITION DEPENDENCIES FUNCTION Pressing the Auto Changeover field in the “System Settings None This functionality sets up the minimum Screen” will invoke the “Auto Changeover Screen” which will time between switching from heat-to- allow a time choice from 5 minutes to 30 minutes for the auto cool or from cool-to-heat demands changeover functionality, adjustable in 5 minute increments when operating in Auto Mode.
  • Page 21 SETTINGS – REMOTE SENSOR DEFINITION DEPENDENCIES FUNCTION Pressing the Remote Sensor None This functionality determines whether the Remote Sensor field in the “System Settings hardware input (JP102) is not used (NONE), is used for the Screen” will invoke the outdoor temperature sensing (OUTDOOR) or used for the indoor “Remote Sensor Screen”...
  • Page 22 SETTINGS – COOL LOCKOUT DEFINITION DEPENDENCIES FUNCTION Pressing the Cool Lockout field in If there is not a valid This functionality is used to hold off the cooling equipment the “System Settings Screen” will outdoor temperature demands if the outdoor air temperature is below the chosen invoke the “Cool Lockout Screen”...
  • Page 23 SETTINGS – TIME BETWEEN FUEL TYPES DEFINITION DEPENDENCIES FUNCTION Pressing the Time Between Fuel Types field in the If there are not This functionality is used to set the “System Settings Screen” will invoke the “Time multiple fuel types, minimum time limit between switching from Between Fuel Types Screen”...
  • Page 24 SETTINGS – CYCLES PER HOUR DEFINITION DEPENDENCIES FUNCTION Pressing the Cycles per Hour field in the “System None Based on the selection of 2, 4, or 6 cycles Settings Screen” will invoke the “Cycles per Hour per hour, this timer is set to 30, 15 or 10 Screen”...
  • Page 25 SETTINGS – HUMIDIFIER DEFINITION DEPENDENCIES FUNCTION Pressing the Humidifier field The HUMIDIFIER CONTROL functionality is In humidification operation, the humidifier in the “System Settings not available if a HP is selected for the Outdoor will be on if there is humidity demand and Screen”...
  • Page 26 SETTINGS – DEHUMIDIFIER DEFINITION DEPENDENCIES FUNCTION Pressing the Dehumidifier Pressing the Dehumidifier field The cool to dehumidify selection tells the system to field in the “System Settings in the “System Settings Screen” operate the compressor, within limits, when there is a Screen”...
  • Page 27 SETTINGS – MAX HEAT SET POINT DEFINITION DEPENDENCIES FUNCTION Pressing the Max Heat Setpoint field in None This feature is used to choose the maximum heating the “System Settings Screen” will invoke setpoint that is available on the Heat Setpoint Wheel the “Max Heat Setpoint Screen”...
  • Page 28 SETTINGS – MIN COOL SET POINT DEFINITION DEPENDENCIES FUNCTION Pressing the Min Cool Setpoint field in None This feature is used to choose the minimum cooling the “System Settings Screen” will invoke setpoint that is available on the Cool Setpoint Wheel the “Min Cool Setpoint Screen”...
  • Page 29 SETTINGS – AUX HEAT LOCKOUT DEFINITION DEPENDENCIES FUNCTION Pressing the Aux Heat Lockout The Aux Heat Lockout functionality If the auxiliary heat lock out temperature setting field in the “System Settings is not available (and will be set to is not OFF and the outdoor air temperature is Screen”...
  • Page 30 SETTINGS – HEAT PUMP LOCKOUT DEFINITION DEPENDENCIES FUNCTION Pressing the HP Lockout The HP Lockout functionality is If a setting of OFF is selected, The heating equipment field in the “System Settings not available with the Outdoor cycle shall always start with the heat pump regardless Screen”...
  • Page 31 SETTINGS – STAGE DELAY DEFINITION DEPENDENCIES FUNCTION Pressing the Stage Delay field in Multiple heating stages or The minimum amount of time the current stage must the “System Settings Screen” will multiple cooling stages must be energized before staging up to the next stage of invoke the “Stage Delay Screen”...
  • Page 32 SETTINGS – FORCED STAGE UP DEFINITION DEPENDENCIES FUNCTION Pressing the Forced Stage Up Multiple heating stages or If time in a current demanded stage reaches the forced field in the “System Settings multiple cooling stages must stage up selected time, the thermostat will stage up to Screen”...
  • Page 33 SETTINGS – DIFFERENTIAL DEFINITION DEPENDENCIES FUNCTION Pressing the Differential field in None This functionality specifies the required difference between the the “System Settings Screen” will current room temperature and the setpoint before demand is invoke the “Differential Screen” initiated. This value is additive for each additional stage of which will allow a temperature equipment being demanded.
  • Page 34 SETTINGS – AIR FILTER REMINDER DEFINITION DEPENDENCIES FUNCTION Pressing the Air Filter Reminder None This functionality defines a chosen number of hours before a field in the “System Settings System Event will occur to remind the homeowner to change the Screen”...
  • Page 35 SETTINGS – AIR FILTER REMINDER DEFINITION DEPENDENCIES FUNCTION Pressing the Air Filter Reminder None This functionality defines a chosen number of hours before a field in the “System Settings System Event will occur to remind the homeowner to change Screen” will invoke the “Air Filter the indoor air filter.
  • Page 36: Auto Allowed

    SYSTEM SETTING RESTORE DEFAULTS SYSTEM SETTINGS DEFAULT Indoor Equip Type FURNACE Indoor Equip Stages Outdoor Equip Type Outdoor Equip Stages Auto Allowed? Prog or Non-Prog PROG Fahrenheit or Celsius °F Smart Recovery Fan On with W Reversing Valve COOL Indoor Temp Offset 0°F SCREEN DEFINITION...

Table of Contents