TOTALINE EZ3 Setting Manual page 35

Wi-fi
Hide thumbs Also See for EZ3:
Table of Contents

Advertisement

SETTINGS – AIR FILTER REMINDER
DEFINITION
Pressing the Air Filter Reminder
field in the "System Settings
Screen" will invoke the "Air Filter
Reminder Screen" which will
allow a setting for equipment
runtime hours choice from OFF to
500 HRS to 15,000 HRS for the
stage delay functionality,
adjustable in 100 hour
increments.
DEPENDENCIES
FUNCTION
None
This functionality defines a chosen number of hours before a
System Event will occur to remind the homeowner to change
the indoor air filter. A System Event will not occur to remind the
homeowner to change the indoor air filter if the OFF setting is
selected. Decrements to the timer will happen each hour of
total equipment runtime is accumulated. Minute counts within
each hour are not stored in non-volatile memory, so a power
reset will clear out the minutes within each hour of run time.
The Filter Reset Reminder hour timer value is stored in non-
volatile memory.
34

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents