SETTINGS – REVERSING VALVE
DEFINITION
Pressing the Reversing Valve field in the
"System Settings Screen" will invoke the
"Reversing Valve Screen" which enables the
reversing valve output (O/B) to either be
activated for heat pump heating or heat
pump cooling demand.
DEPENDENCIES
FUNCTION
This functionality is
This functionality defines whether the ON state of
only used in
the reversing valve is used for Heating or Cooling.
operational logic if a
When the ON state of the reversing valve is used
Heat-Pump is chosen
for Cooling, the signal is typically referred to as a
as the Outdoor
"O" demand. When the ON state of the reversing
Equipment Type.
valve is used for Heating, the signal is typically
referred to as a "B" demand.