HIOS VZ SERIES Operation Manual
Hide thumbs Also See for VZ SERIES:

Advertisement

Transformerless Screwdriver
111-6, Akiyama, Matsudo City, Chiba, Pref. Japan
TEL. 81-47-392-2001 FAX. 81-47-392-7773
08
A
Electric
Screwdriver
Operation Manual
(November, 2008)
VZ SERIES 100V
Lever Start Type
Push To Start Type
VZ SERIES 220 - 240V
Lever Start Type
Push To Start Type
R
VZ-1510
VZ-1510PS
VZ-1812
VZ-3007
VZ-4504
VZ-1812PS
VZ-3007PS
VZ-4504PS
Operation Manual No. ET-A004

Advertisement

Table of Contents
loading

Summary of Contents for HIOS VZ SERIES

  • Page 1 Screwdriver Operation Manual (November, 2008) Transformerless Screwdriver VZ SERIES 100V Lever Start Type VZ-1510 Push To Start Type VZ-1510PS VZ SERIES 220 - 240V Lever Start Type VZ-1812 VZ-3007 VZ-4504 Push To Start Type VZ-1812PS VZ-3007PS VZ-4504PS 111-6, Akiyama, Matsudo City, Chiba, Pref. Japan TEL.
  • Page 2 SAVE THESE INSTRUCTIONS We thank you for your purchase of Hios Electric Screw Driver. WARNING When using electric tools, basic safety precautions should always be followed to reduce the risk of fire, electric shock and personal injury, including the following: READ ALL INSTRUCTIONS 1.
  • Page 3 10. Dress Properly. Do not wear loose clothing or jewelry. They can be caught moving parts. Wear protective hair covering to contain long hair. 11. Use Safety Glasses. Also use face or dust mask if operation is dusty. 12. Don't Abuse Cord. Never carry tool by cord or yank it to disconnect from receptacle.
  • Page 4 TABLE 1 MINIMUM GAGE FOR CORD SETS Volts Total Length of Cord in Feet 120V 0 - 25 26 - 50 51 - 100 101 - 150 240V 0 - 50 51 - 100 101 - 200 201 - 300 Ampere Rating More Not More...
  • Page 5: Grounding Instructions

    GROUNDING INSTRUCTIONS The tool should be grounded while in use to protect the operator from electric shock. The tool is equipped with a three-conductor cord and three-prong grounding-type plug to fit the proper ground- ing-type receptacle. The green (or green and yellow) conductor in the cord is the grounding wire.
  • Page 6: Cautions In Operation

    Please use this tool with caution, as Carpal Tunnel Syndrome (CTS) or other trauma disorders may result. HIOS shock-Resistant Stand is available to absorb the torque to the operator's hand during operation.
  • Page 7 SUMMARY This VZ Series Screw Driver is a Control Function Built-in Type. The body is light and designed to decrease the vibration and noise. It is possible to use hexagonal bit with opposite side of 6.35mm (1/4 inch. HEX.) Also, you can select the starting system (Lever Start and Push to Start) in accordance with the work.
  • Page 8: Parts Name

    1. Parts Name Lever start Push to start AC plug Power Cable Hanger Hanger Foward/off/ Carbon reverse switch brush cap Carbon Carbon brush cap brush cap Carbon brush cap Foward/off/ reverse switch Switch lever Switch lever Adjsuting bolt (Torque adjsut scale) Torque adjust Torque adjusting bolt scale nut...
  • Page 9: How To Use

    HOW TO USE OPERATION 1. Insert the Bit into the Joint Shaft Collar of the ScrewDriver. 2. Turn the Torque Adjusting Nut and adjust the tighten- ing torque. 3. Make sure the Forward/Off/Reverse Switch is in the "OFF" position. 4. Insert the AC Plug into the AC 220 -240V socket. (AC100V for VZ-1510, VZ-1510PS) 5.
  • Page 10 • The VZ-1812 series and VZ-3007 series has a chuck to suit both the HIOS shank H5 (Ø5) and the 5 mm wide hexagonal bit (5HEX). Take note of the following precautions when using the hexagonal bit. • Always use our standard HIOS shank type bits H4 (Ø4) and H5 (Ø5).
  • Page 11 (Caution) 5mm wide Hexagonal Bit When using the 5 mm wide Hexagonal W Bit, 5mm wide tighten the Phillips adjustment screw 14mm (supplied screw) tightly into the driver bit chuck. * If the Phillips adjustment screw is not tightened for enough, the driver bit will not be locked and may result in unreliable screw fastening.
  • Page 12 Torque adjusting nut strongly fasten the Nut fixing ring by holding the Torque adjusting nut. We recommend to use the HIOS Torque meter Tools to set the torque of Screw Driver or to check the torque of screw. (HP, HDP series) •...
  • Page 13 How to change the Carbon Brush (Caution) Whenever changing the Carbon Brush, AC plug should be unplugged. • Unscrew the slotted Carbon Brush Cap by Slotted Screw ( - ) Driver and remove it. • When the Carbon Brush Cap is changed, pay attention to the direction of brush surface (concav- ity).
  • Page 14 Approximate Guidance of Output Torque VZ-1510 VZ-1510PS • N·m Torque Adjustment Scale (Upper edge of Nut) 1 2 3 4 5 6 7 Torque Scale VZ-1812 VZ-3007 VZ-1812PS VZ-3007PS 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 Torque Scale Torque Scale VZ-4504...