SUB–123P OWNER'S MANUAL
Fig. #2 – Power Supply Connections
E.
Engage the main power supply.
F.
Check the voltage at the terminals on the Power Terminal Block with a voltmeter and compare the
readings with the label listings on the side of the unit. If the readings match, the unit is ready for
its initial START-UP. If the readings DO NOT coincide you must call the NU-VU
Department.
G. Install any required or desired drain plumbing to the drain fitting in the base of the unit directly
under the proofer compartment.
H. Replace the Outside Top. Be careful not to pull or pinch any wires while installing the Panel.
I.
Install nine of the supplied Shelves [65] in the Proofer. The other Shelves are used in the Oven.
J.
Push the unit back into place and set the brakes on the front Casters.
K. The Proofer compartment of the NU-VU
directly under the Proofer Door. Please install the included Drain Pan [77] in the brackets under
the Proofer if you have not already installed drain plumbing. This drain prevents the build-up of
excessive water that may damage the Proofer Motor, Heating Element, or a Sensor.

Connection of Water Supply - -

This equipment must be installed in accordance with all applicable federal, state, province, and/or local
plumbing codes having jurisdiction.
®
NU-VU
strongly recommends that SOFT WATER ONLY be used in any unit requiring a water supply.
Also, a good quality water filter must be installed in-line between the unit connection and the water supply
to guard against clogging and mineral build-up in the components. This is extremely important in areas
having hard water. The water filter may be installed at the water source, adjacent to the water inlet on the
unit, or anywhere in between, whichever is more convenient for you.
Run 1/4" OD tubing from the water supply line to the unit location. Allow some slack in the
A.
tubing for final unit positioning and any future service requirements. Avoid any kinks or strains
on the tubing, and position the tubing where it will not be damaged in any way.
B.
The tubing end that attaches to the back of the unit must not be damaged or deformed in any way.
The cut end should be cut straight and clean with no deforming of the tubing. All burrs and sharp
or rough edges should be removed to ensure a proper and leak-free connection.
C.
Position the tubing so that it runs straight into the intake Water Fitting [76] on the rear of the unit.
Be careful not to kink the tubing if you bend it, and do not bend the tubing within two (2) inches
of the cut end.
The two-part compression fitting (tapered collar and nut) is placed approximately 1" onto the end
D.
of the tubing so that the collar is inside of the nut and the threaded opening of the nut is toward
the intake Water Fitting.
®
NU-VU
FOOD SERVICE SYSTEMS
(906) 863-4401
®
SUB-123P is equipped with a bottom drain centered
Sales Fax (906) 863-5889 ♦ Service Fax (906) 863-6322
RECEIPT, INSTALLATION AND START-UP
MENOMINEE MICHIGAN 49858-1029
®
Service
5
page

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents