Technical Data - Emerson 2120 Quick Start Manual

Level switch
Hide thumbs Also See for 2120:
Table of Contents

Advertisement

December 2016
Aggressive substances – e.g. acidic liquids or gases that may attack metals or
solvents that may affect polymeric materials.
Suitable precautions – e.g. regular checks as part of routine inspections or
establishing from the material's data sheet that it is resistant to specific
chemicals.
7. The Rosemount 2120 meets the requirements of clause 6.3.12 (Isolation of
circuits from earth or frame) in EN 60079-11 (IEC 60079-11).

8. Technical data:

a. Coding:
: II 1 G D, Ex ia IIC T5...T2 Ga, Ex ia IIIC T85 °C...T265 °C Da
ATEX
: Ex ia IIC T5...T2 Ga, Ex ia IIIC T85 °C...T265 °C Da
IECEx
b. Temperature:
2120***H*I1**, 2120***H*I7**:
Temperature
classes
T5, T4, T3, T2, T1
T4, T3, T2, T1
T3, T2, T1
Minimum ambient air temperature (Ta) = –40 °C
Minimum process temperature (Tp) = –40 °C
2120***K*I1**, 2120***K*I7**:
Temperature
classes
T5, T4, T3, T2, T1
T4, T3, T2, T1
T3, T2, T1
Minimum ambient air temperature (Ta) = –40 °C
Minimum process temperature (Tp) = –40 °C
c. Input parameters:
NAMUR electronics:
Ui =15 V, Ii = 32 mA, Pi = 0.1 W, Ci = 12 nF, Li = 0.06 mH
8/16 mA electronics:
Ui = 30 V, Ii = 93 mA, Pi = 0.65 W, Ci = 12 nF, Li = 0.035 mH
d. Materials:
See the Rosemount 2120
e. Year of manufacture: printed on product label
Maximum surface
temperature (T)
T85
T120
T155
Gas (Ga)
Maximum
Maximum
ambient air
process
temperature
temperature
(Ta)
(Tp)
°
80
C
60
°
60
C
115
°
50
C
150
Gas (Ga) and Dust (Da)
Maximum ambient air
temperature (Ta)
°
C
°
C
°
C
Maximum
surface
temperature
(T)
°
C
T85
°
C
T120
°
C
T155
Product Data Sheet
Quick Start Guide
Maximum process
temperature (Tp)
°
80
C
°
60
C
°
50
C
Dust (Da)
Maximum
ambient air
temperature
(Ta)
°
70
C
°
60
C
°
50
C
or
Reference
Manual.
°
60
C
°
115
C
°
150
C
Maximum
process
temperature
(Tp)
°
60
C
°
115
C
°
150
C
25

Advertisement

Table of Contents
loading