TESTING

1. Testing Hold-Up Actuators

ACTION
Press
TEST
Enter your ID #.
Enter your CODE #.
NOTE 1: The test period lasts seven minutes.
Hold-up actuators automatically reset at the end of the test.
To accept
HOLD-UP TEST, press
Enter the AREA # for
which you want hold-up
actuator testing.
NOTE 2: "HOLD-UP # # " indicates the ID number of the tested actuator.
This actuator remains displayed until a new actuator is activated or
until the test period is ended.
Activate other
hold-up actuators.
NOTE 3: Repeat the procedure for all hold-up actuators you wish to test.
To exit
HOLD-UP TEST, press
NOTE 4: At the end of the hold-up test, all actuators are automatically reset.
Any further testing results in a FALSE POLICE DISPATCH.
To exit, press
MESSAGE
ID ? –
ID ? # #
CODE ? – – – –
TEST MENU
HOLD UP TEST
AREA ? –
HOLD-UP TEST
HOLD-UP TEST
HOLD-UP # #
END-H-U TEST
TEST MENU
HOLD-UP TEST
** INTELLIGUARD 9000 **
yy/mm/dd hh:mm
SIGNAL
2 BEEPS
2 BEEPS
1 BEEP EVERY
Flashing
2 SECONDS
2 BEEPS
Flashing
BEEPING AT
FASTER RATE
19