2624, 2624S, 2636, 2636S Griddle
INSTALLATION
FILLING BOILER WITH WATER:
CAUTION: MAKE SURE POWER IS OFF AND GRIDDLE IS COOL.
TURN OFF WATER SUPPLY:
Locate boiler water fill valve located front right of the griddle and remove caps (A & B). Locate purge valve
left back of griddle inside power head and remove caps (C & D). Detach existing water fill hose rear of
unit (F) and attach to boiler water fill located front right of griddle (A). Open valve; allow water to run until
water exits purge valve then close purge valve. Close fill valve. Turn water line at its source and disconnect.
Replace caps on all fittings.
3