Trouble-Shooting - Market Forge Industries 2624 Owner's Manual

Electric purr-fect height steam shell griddle convection oven combo 2624s and 2636s with steam; 2624 and 2636 without steam.
Table of Contents

Advertisement

2624, 2624S, 2636, 2636S Griddle
The griddle is designed to operate smoothly and efficently is properly maintained. However, the following is
a list of checks to make in the event of a problem.
Wiring diagrams are furnished inside the service panel as well as in this manual.
IF AN ITEM ON THE LIST IS FOLLOWED BY AN (*), THE WORK SHOULD BE DONE BY A QUALI-
FIED SERVICE AGENT.
PROBLEM
LOW WATER IN BOILER
HEATER(S) NOT WORKING
GRIDDLE HOTTER THEN SET POINT
GRIDDLE HEATS UP TOO SLOWLY
GRIDDLE NOT HEATING UP
UNEVEN SURFACE TEMPERATURE
NO POWER
NO STEAM COMES OUT OF NOZZLE
STEAM GENERATOR WATER LOW
NOT ENOUGH STEAM PRESSURE
HEATER(S) NOT WORKING

TROUBLE-SHOOTING

PROBABLE CAUSE
1. Steam system leak.
1.
Unit not wired properly.
2.
Heater(s) bad.
3.
Contactor or solid state relays not
working.
4.
Failed temperature controller.
1.
Temperature controller out of cali-
bration.
2.
Thermocouple sensor defective.
3.
Solid stare relay(s) stuck on.
4.
Failed temperature controller.
1.
Heater(s) not working.
2.
Too much water in boiler.
1.
Temperature control not set high
enough.
2.
Low water in boiler.
3.
Failed temperature controller.
4.
Heater(s) not working.
1.
Air in system.
2.
Low water in boiler.
1.
Power switch off.
2.
Not plugged in.
3.
Breaker off or tripped.
1.
Start up procedure not done.
2.
Steam generator low on water.
3.
Lid not closed.
4.
Heater(s) not working.
5.
Steam solenoid defective.
1.
Water supply to steam generator off.
2.
Water solenoid plugged or defective.
1.
Heater(s) not working.
2.
Pressure switch out of adjustment or
defective.
3.
Pressure switch waterlogged.
1.
Wired incorrectly.
2.
Heater(s) bad.
3.
Pressure switch out of adjustment or
defective.
4.
Pressure switch waterlogged.
9
REMEDY
1. Repair leak.*
1.
Check wiring.*
2.
Replace heater(s).*
3.
Repair or replace.*
4.
Replace temperature controller.*
1.
Recalibrate temperature controller.*
2.
Replace thermocouple.*
3.
Replace solid state relay(s).*
4.
Replace temperature controller.*
1.
Purge air per instruction.
2.
Remove excess water.
1.
Adjust to desired temperature.
2.
See "low water in boiler".
3.
Replace temperature controller.*
4.
See "heater(s) not working".
1.
Check water level and purge air from
system. Check for leaks.
2.
Check water level in boiler. Add
water if needed.
1.
Turn on power switch.
2.
Check plug.
3.
Check breaker.
4.
Check for shorts.*
1.
Perform "start up procedure".
2.
See "steam generator water low"/
3.
Lid must be closed to activate steam.
4.
See "heater(s) not working".
5.
Replace.
1.
Check water supply.
2.
Repair or replace.*
1.
See "heater(s) not working".
2.
Repair or replace.*
3.
Restore air trap for pressure switch
and repair air leak.
1.
Check wiring.*
2.
Replace heater(s).*
3.
Repair or replace.*
4.
Restore air trap for pressure switch
and repair air leak.