The kit contains a U-shaped piece, a vented
front cover, 2 side covers, two front brackets
and the required hardware to assemble. See
the exploded view of the installation, illustra-
tion
130BA647).
The pedestal has been partially assembled.
Before installing the drive on to the pedestal,
it is important to anchor the pedestal to the
floor using the four pedestal mounting holes.
The holes can accommodate up to M12 bolts
(not included in the kit).
CAUTION: The drives are top heavy and may
fall over if the pedestal is not anchored to the
floor.
The entire assembly may also be supported by
using the drive top mounting holes to anchor
it to a wall structure.
The completely assembled pedestal with ven-
ted front cover and two side covers installed.
Multiple adjustable frequency drives may be
mounted side by side. The interior side closing
plates are left off.
NOTE: The front and side cover mounting
screws are now recessed M6 Torx socket flat
head screws.