Use Of Main Vacuum Unit; Stop And Start Control - GENERAL D'ASPIRAZIONE i1250 Use And Maintenance Manual

Residential vacuum unit gda series
Table of Contents

Advertisement

Use and Maintenance Manual
Residential Vacuum Units

5. Use of main vacuum unit

Important
The system is designed for use by one operator only. For motives of efficiency only one
suction point may be used (open) at a time.
Important
Before starting to use the system check that all system components are in place.

5.1 Stop and start control

The main vacuum unit can be turned on and off in two different ways:
1. Using the wireless command.
All vacuum unit versions are equipped with a wireless receiver. It is therefore sufficient to press the
start/stop button on the BRAVA Wireless Handle to turn the main vacuum unit on and off.
IMPORTANT
It is not necessary for the suction points to be fitted with electrical wiring for consent
leading to the main vacuum unit.
2
Using the suction point consent function.
Simply insert the operating hose into the required suction point. To turn off the main vacuum unit it is
sufficient to remove the operating hose from the suction point.
IMPORTANT
Suction points must be fitted with electrical wiring for consent leading to the main
vacuum unit.
Connect the two pole of color (black,red) of cable 7x0,25 to the two command's wires
of low voltage 5Vdc to the socket line.
Figure 17
>>> Use of main vacuum unit