Use and Maintenance Manual
Residential Vacuum Units
CAUTION: Electrical connections must be made only by qualified personnel.
7. Connect the two coloured poles (black, red) of the 7x0.25 cable to the two wires of the 5 Vdc low-
voltage command of the INLETS LINE.
8. If you are using the Brava Wireless Handle, it is not necessary for the suction points to be fitted with
electrical wiring for consent leading to the main vacuum unit.
. For the Intelligence and Total versions, connect the 5 poles (yellow, green, grey, white, blue) for the
9
direct auxiliary signal to the embedded user interface. The use of this signal is OPTIONAL.
10. Insert the power supply plug into the electrical socket.
11. Perform the system trial.
At the completion of the installation it is recommended to perform a control
of the main vacuum unit fixation and stability.
Ask the installer to perform the testing and calibration of the system to authenticate the
installation in a workmanlike.
Indication DO NOT power the vacuum unit until the completion of sockets receptacles,
and the Remote Panel.
>>> Residential Vacuum Units Installation