NetAXS-123 Startup Guide, Document 800-05780V2
TABLE OF CONTENTS
1) Introduction ............................................................................................ 3
2) Before You Start ..................................................................................... 3
4) Powering Up ........................................................................................... 4
1) Introduction
This document describes the basic setup, wiring and configuration steps
needed for the NetAXS-123 access control system.
NetAXS-123 can be configured in many different ways, depending on the
specific needs of the end-users. This document covers a single panel, 1 door
system. Additional doors are set up, wired and configured in a similar
manner to the first door. This document does not cover all of these
configurations.
For further configuration and setup information including installations related
to WIN-PAK and/or RS-485 communications please consult the NetAXS-123
User Guide and NetAXS-123 Installation Guide; both on NetAXS-123
Product CD.
©
2013 Honeywell, Inc. www.Honeywell.com
2) Before You Start
1. Verify factory default DIP switch settings
(Address 1, Gateway Panel) as shown below:
1 2 3 4 5 6 7 8 9 10
NOTE:
Actual DIP switch orientation may vary depending on the panel
mounting orientation. Please refer to Appendix G for more information on DIP
switch configuration.
If using EVL, DIP switch addresses are not used as
addressing is configured in the web browser. Refer to Appendix A for
additional details.
2. Determine the power source: Power Over Ethernet (PoE) or 12VDC
power supply.
NOTE:
If using PoE, a total maximum of 450ma @ 12VDC is available
for all external devices (locking device, reader(s), input and output devices).
3. Determine communications source: IP/Ethernet or USB.
4. Determine relay configuration (see the circuit diagram on Page 2).
•
Power at relay terminals:
Whetted 12VDC (factory
default) or External (EXT)
power source:
•
Relay Type: Normally Closed
(NC) or Normally Open
(NO, factory default):
External (EXT) Power
Whetted 12VDC
+12V
NC
+12V
NC
EXT
NO
EXT
NO
Normally Closed (NC)
Normally Open (NO )
+12V
NC
+12V
NC
EXT
NO
EXT
NO